■ Actions after Replacement the Parts
1. Clear parts counter.
Service Mode > COPIER > COUNTER > DRBL-2 > PF-TR-SL

Removing the C-fold Stopper Solenoid (SOL5)

■ Preparation
1. Open the front
cover."Open the Front cover" on page 64
2. Open the feed guide.
3. Draw out the folding unit.
4. Remove the right inner cover.
■ Procedure
1. Release the harness from the wire saddles to remove the C-fold stopper solenoid unit.
• 1 Screws
• 1 Connector
■ Actions after Replacement the Parts
1. Clear parts counter.
Service Mode > COPIER > COUNTER > DRBL-2 > PF-ST-SL

Removing the Through-pass Inlet Antistatic Needle

■ Preparation
1. Open the front cover.
"Open the Feed Guide" on page 65
"Drawing out the Folding Unit" on page 71
"Removing the Right Inner Cover" on page 70