STEP 6: Remove the housing exposing the motor/blower assembly.
STEP 7: Remove 7/16" nuts holding motor/blower assembly in place.
STEP 8: Drop motor/blower assembly out of unit. Be careful as wire connection are still in place.
STEP 9: Disconnect plug and play connection connecting wires from motor to control box.
30
FAN FILTER UNIT - Manual | priceindustries.com
FIGURE 32: 2X2 MOTOR-BLOWER HOUSING REMOVAL
(STEP 1).
FIGURE 33: MOTOR-BLOWER HOUSING REMOVAL (STEP 2).
FIGURE 34: SPEED CONTROL AND MOTOR HARNESS CABLES