3.4.2 Supply Currents

3.4.3 Power Supply Guidance

The NV9 Spectral requires a stable 12 V DC / 3 A power supply. Please check the
power requirements of the host machine and other peripherals to dimension a
suitable power environment for the machine setup.
TDK Lambda manufactures suitable power supplies. Please see table below for
further details.
Power Supply Unit
TDK Lambda SWS50-12
TDK Lambda SWS75-12
TDK Lambda SWS150-24

3.5 Interface Logic Levels

Interface Logic Levels
Inputs
Outputs with 2K2Ω pull-up resistor
Maximum Current Sink
Copyright © Innovative Technology Ltd 2018
Phase of operation
Standby
Running (RMS)
Peak
Caution!
Power must always be connected.
Specification
+12 V DC / 4.3 A
+12 V DC / 6.3 A
+24 V DC / 6.3 A
Logic Low
0V to +0.5V
+0.6V
50mA per Output
Current draw (max)
200mA
1 A
2.5 A
RS Stock Code
Farnell Stock Code
466-5869
1184645
466-5904
1184648
466-5982
1184653
Logic High
+3.7V to +12V
Pull-up voltage of host interface
Doc:PA02093
Version: 1
Page 12 of 26