Eaton ePDU G3 Operating Manual page 141

Enclosure power distribution unit
Hide thumbs Also See for ePDU G3:
Table of Contents

Advertisement

Table 11. ePDU and User Alarms and Events (Continued)
Identification and
Type Code
Index Code
2
215200
2
215300
2
215400
2
216000
2
216100
2
221000
2
221100
2
221200
2
221300
2
221400
2
222000
2
222100
2
222200
2
222300
2
222400
2
223000
2
223100
2
241000
2
241100
2
251000
2
251100
2
231000
Alarm or Event
ePDU Input 2 Low Voltage Critical
ePDU Input 2 High Voltage Warning
ePDU Input 2 High Voltage Critical
ePDU Input 2 Frequency OK
ePDU Input 2 Frequency out of +/- 3 Hz
tolerance
ePDU Gang Phase Input Current No
Threshold
ePDU Gang Phase Low Current Warning
ePDU Gang Phase Low Current Critical
ePDU Gang Phase Over Current Warning
ePDU Gang Phase Over Current Critical
ePDU Gang Phase Voltage No Threshold
ePDU Gang Phase Low Voltage Warning
ePDU Gang Phase Low Voltage Critical
ePDU Gang Phase Over Voltage Warning
ePDU Gang Phase Over Voltage Critical
ePDU Gang Not Alarmed
ePDU Gang Alarmed
Communication OK
Communication Lost
Daisy Chain Communication OK
Daisy Chain Communication Alarmed
ePDU Outlet Current No Threshold
Eaton ePDU G3 Operation Manual P-164000277—Rev 5
Maintenance and Alarms
Description
The specified section voltage reading is less than the
value configured as the low voltage critical threshold.
The specified section voltage reading is greater than
the value configured as the over voltage warning
threshold.
The specified section voltage reading is greater than
the value configured as the over voltage critical
threshold.
The frequency is not out of range.
The frequency is out of range.
No section current threshold has been triggered.
The current amperage (A) reading for the specified
section is less than the value configured as the low
current warning alarm threshold.
The current amperage (A) reading for the specified
section is less than the value configured as the low
current critical alarm threshold.
The specified section current amperage (A) reading is
greater than the value configured as the over current
warning threshold.
The specified section input current amperage (A)
reading is greater than the value configured as the
over current critical alarm threshold.
No section voltage threshold has been triggered.
The specified section voltage reading is less than the
value configured as the low voltage warning
threshold.
The specified section voltage reading is less than the
value configured as the low voltage critical threshold.
The specified section voltage reading is less than the
value configured as the over voltage warning
threshold.
The specified section voltage reading is less than the
value configured as the over voltage critical
threshold.
No alarm has been triggered.
An alarm has been triggered.
No communication failure detected on Teridian
RS-485 bus
Communication failure detected on Teridian RS-485
bus
No communication failure detected on Daisy Chain
Communication failure detected on Daisy Chain
No outlet current threshold has been triggered.
132