Flexishield® Food Shields Installation; Mobile Hand Sink Installation - Delfield Concepts Installation Manual

Serving systems
Hide thumbs Also See for Concepts:
Table of Contents

Advertisement

Concepts Installation Manual
FlexiShield ® Food Shields Installation
1. Set food shield on base unit. See Figure 1.
2. Line base over holes.
Install screws (provided) into predrilled holes. See Figure 2.
Place 2 dabs of silicone on screws and place cover over screws.
3. Make any necessary electrical connections.
4. If applicable test lights, heat lamps etc.
5. Adjust glass for proper alignment and ensure that all hardware is
tightened securely.
6. Clean food shield and glass with mild soap and water.
FlexiShield® food shields are to be used as food and counter protection
only and should not be used in any other way.

Mobile Hand Sink Installation

The hand sink is to be used for hand washing
only, not for consumption.
Hot water heater MUST be filled with water
before connecting the water heater to power
to prevent damage to the heater.
The fresh water and waste water containers are located in
the base of the sink compartment on the right. The fresh
water containers are on the left with clear vinyl tubing
and waste water tanks are on the right with a rigid drain
tube. Two fresh water and two waste water containers
are provided with each unit.
To add water to the fresh water container, remove the
cap the vinyl tubing is connected to on the container by
pressing the button on the cap and pull out the cap from
the container. Pull the container out of the sink base and
unscrew the cap of the fill access hole at the back of the
container. Fill the container with water and screw the cap
back on at the back of the container and push the cap with
the vinyl tubing back into place at the front. Make sure
there are no kinks in the clear vinyl tubing.
12
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Figure 1. Food shield over holes
Figure 2. Flange dimensions
Verify the black waste arm at the end of the drain line is in
the hole on the waste container.
Before Operating The Sink:
Water heater MUST be filled with water before connecting
the water heater to power to prevent damage to the heater.
Before plugging the sink into a wall receptacle, verify the
water pump only is plugged into the GFCI receptacle in
the base of the unit. If the water heater is plugged in,
unplug it until the heater has been filled with water. Put
the switch and the breaker to the "ON" position in the
base of the unit. Make sure the GFCI receptacle is ON.
To fill the water heater with water, turn on the hot water
handle on the faucet until water flows. When water flows
into the sink, the water heater is filled with water. The
water heater can now be plugged into the GFCI receptacle.
Verify the water heater power switch on the front of the
heater is ON. The red light on the switch will stay on until
it has reached the set temperature.

Advertisement

Table of Contents
loading

Table of Contents