A(mm)
760
Before installation
•
The work surface is square and level, and no structural members interfere with space requirements.
•
The work surface is made of a heat-resistant material.
•
If the hob is installed above an oven, the oven has a built-in cooling fan.
•
The installation will comply with all clearance requirements and applicable standards and regula-
tions.
•
A suitable isolating switch providing full disconnection from the mains power supply is incorporated
in the permanent wiring, mounted and positioned to comply with the local wiring rules and regula-
tions.
•
The isolating switch must be of an approved type and provide a 3 mm air gap contact separation
in all poles (or in all active [phase] conductors if the local wiring rules allow for this variation of the
requirements).
•
The isolating switch will be easily accessible to the customer with the hob installed.
•
You consult local building authorities and by-laws if in doubt regarding installation.
•
You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall surfaces sur-
rounding the hob.
After installation
•
The power supply cable is not accessible through cupboard doors or drawers.
•
There is adequate flow of fresh air from outside the cabinetry to the base of the hob.
•
If the hob is installed above a drawer or cupboard space, a thermal protection barrier is installed
below the base of the hob.
•
The isolating switch is easily accessible by the customer.
B(mm)
C(mm)
50 mini
20 mini
19
D
E
Air intake
Air exit 10mm