"read_public_information": true,
"group": 1,
"range_from": 1,
"range_to": 100
}
}
7.3.3.4
Lock response
Every 3rd party SW answer will be replied by the lock sending a final response. This
response can contain two different structures. First one will be for all the
opening/closing operation + card configuration + lock configuration and the last one
will be the answer to the information request.
7.3.3.4.1
LOCK RESPONSE TO OPENING/CLOSING PETITION
(INCLUDING CARD CONFIGURATION AND LOCK
CONFIGURATION)
Definition
Lock will always answer the last event that happened in the lock, that includes
event type, uid that performed the action, time and date that happened.
Parameters
A JSON structure will be received by TCP/IP with following parameters.
Parameter
Log_items
log_item
Timestamp
eventCode
battery_status
Example
{
logItems=[LogItem [timestamp=1476885376, uid=00000667BE4404
, eventCode=EventType[USER_CLOSE: 18], batteryStatus=73]]
}
7.3.3.4.2
LOCK RESPONSE TO OPENING/CLOSING PETITION
(INCLUDING CARD CONFIGURATION AND LOCK
CONFIGURATION) + INFORMATION REQUEST
Lock installation & subinstallation request
7_API REFERENCE MANUAL
Mandatory
Yes
Yes
Yes
Yes
Yes
Data type
Array ()
Array(string)
String
String
String
Possible values
Unix format.
Event code +
description (See
Annex).
% of battery level.