This key deletes all the configuration from the lock and resets it to its factory configuration. Therefore, a set-up key must be used to restart it. 1.1.7. Test Key This key allows a lock to be opened and closed when it is factory configured. OJMAR...
Flash (First and long) Very Long 2 sec Date and time Flash recorded correctly on lock. Very Long 2 sec Winter/summer Flash time changes recorded correctly on lock. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 2 _ PORTABLE PROGRAMMER...
2. PORTABLE PROGRAMMER 2.1. OJMAR NFC MODEL PROGRAMMER Touch screen. Key reading area: The keys must be placed in this area so that they can be read/ recorded by the programmer. Screen On/Off. On: Press the button quickly (a beep will be heard).
2.1.1. Main Screen The main screen of the Ojmar NFC programmer displays the following information: Operations with keys: See Section 2.1.2. Operations with locks: See Section 4.1.1. Configuration. Date and time: Displays the date and time of the programmer. This information will be used when recording the locks and keys.
Attach key. By placing the key over the key reading area of the programmer, the information associated to it is displayed. • EXAMPLE: In this case, a service key has been read and the reading is correct. 2 _ PORTABLE PROGRAMMER OJMAR...
Page 12
Attach key. By placing the key over the key reading zone of the programmer, the key will be read. • EXAMPLE: In this case, a “Free” key has been read and the reading is correct. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 3 _ OTS MANAGEMENT SOFTWARE...
3.1. ACCESSING THE APPLICATION, CONFIGURATION, START-UP AND GENERAL OPTIONS A user name and password are requested on accessing the application. The “Licence” folder of the installation CD contains a file called “default user” that includes the operator name and password. 2 _ PORTABLE PROGRAMMER OJMAR...
Page 15
Once inside the application, the following main screen is displayed: 15 16 • NOTE: The main screen displays the locks screen by default. 3 _ OTS MANAGEMENT SOFTWARE OJMAR...
Select the communications port where the programmer is connected. • NOTE: See Section 3.3 for information on the communications port (COM) that is connected to the programmer. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 3 _ OTS MANAGEMENT SOFTWARE...
Communications must be established with the programmer before you can use the keys. To do so: Select programmer type: Select between the Ojmar NFC or CNReader programmer COM port number: Click on the following icon for the communications port (COM) to be automatically detected and press save button.
3. Select the subgroup to which the key belongs (more than one subgroup can be selected). 4. Press write card. • NOTE: The rest of the fields are optional. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 3 _ OTS MANAGEMENT SOFTWARE...
*above the lock number with a dedicated key already created. 4. Press write card. • NOTE: The rest of the fields are optional. 3 _ OTS MANAGEMENT SOFTWARE OJMAR...
(see Section 3.3). WRITE A TIME SET KEY: 1. Place a blank card on top of the programmer. 2. Click on set time. 3. Press write card. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 3 _ OTS MANAGEMENT SOFTWARE...
Page 21
7. Then pass the initialisation card in all the system’s dedicated locks by pressing the knob of the lock consecutively, starting on the lock with the number selected in the first lock (step 3) and ending with the number selected in the last lock (step 4). 3 _ OTS MANAGEMENT SOFTWARE OJMAR...
A maximum of 96 locks can be loaded. 7. Click on update. 8. If the operation has been carried out correctly an updated message will come up. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 3 _ OTS MANAGEMENT SOFTWARE...
Page 23
THEN THE INITIALISATION DATA HAS TO BE SENT TO THE LOCKS WITH THE PROGRAMMER: 1. Click on the operations with locks icon. 2. Click on the OTS Advance icon. 3. Click on the Initialise icon. 4. Click on the Set up lock icon.
3.6. EVENTS The locks are able to store accesses and actions that have occurred on them. The Ojmar NFC programmer or an events key must be used to collect these movements. The events screen displays these movements. Access this screen via the “Communications / Events” menu or by clicking on the following...
Page 25
List of events: This list displays the events recorded on the events key or in the Ojmar NFC programmer. Example: • The lock number used. • Action taken on the lock. • User to have performed the event. • Key used.
Page 26
READ EVENTS WITH THE OJMAR NFC PROGRAMMER: To collect the events of one lock with the Ojmar NFC programmer the following steps are to be carried out: 1. Turn on the programmer 2. Click on the “Operations with locks” icon.
4. MAINTENANCE AND FAQs 4.1. MAINTENANCE Ojmar locks automatically detect low battery levels. When this occurs, the yellow LED flashes 3 times for each opening or closure cycle performed. Up to 9 opening and closure cycles are possible as of the time when the low battery is detected.
• Test: Performs a test on the lock and displays the results on the screen. Press “Operations with locks”. Press “OTS Advance”. Pres “Test”. Bring the programmer reader towards the knob of the lock and press it inwards. OTS ADVANCE _ QUICK GUIDE _ VERSION 3.1 4 _ MAINTENANCE AND FAQs...
When collecting events of a The lock has not Add the lock, following the steps given in lock using the Ojmar NFC been added to the Section 3.5.2. programmer, the following list of locks in the message is displayed on the programmer.
Page 30
Polígono Industrial de Lerun, s/n 20870 Elgoibar · Spain T. +34 943 748484 www.ojmar.com...