Troubleshooting Guide - Carlisle MS Series Service Manual

Powder spray gun
Table of Contents

Advertisement

EN

TROUBLESHOOTING GUIDE

General Problem
No electrostatics
and no powder
output
No electrostatic
(e.g. no wrap
around or no
powder adhesion)
Worse wrap around
Back spray
Powder outlet
insufficient
Spray cloud no
longer correct
PA-17-07-R1 (08/2018)
Possible Cause
Defective fuse on the controller
Error at the high-voltage generation
Defective Cascade in spray gun
Defect electric cable from gun to
Controller
Incomplete grounding
No grounding
Compressed air main supply
insufficient
Feed air - dosage air ratio incorrect
Worn collector nozzle, propelling nozzle
in the injector
Worn nozzle system
Replace fuse
Contact MS Service
Contact MS Service
Contact MS Service
See chapter Grounding
See chapter Grounding
Check the air supply
Feed air, dosage air check to Controller
Check, Replace
Replace nozzle system
31 / 39
MAINTENANCE
Solution
www.carlisleft.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms topcoat m4

Table of Contents