INSTALLATION

2.18.2 Parameters' list

Parameters are listed base on the reference menu.
Reference Menu
M1
Boiler parameters menu
M2
System cascade settings menu
M3
Boiler cascade settings menu
M4
Appliance configuration menu
Nr. dis-
Par.
Menu
played
No.
Display
Defines the boiler's various heating operation
M1
1
CH mode
CH set-
Defines the desired supply temperature in heating
M1
3
point
Calc.
Establishes the set-point offset value calculated in
set-
M1
109
climatic mode (Par. 1= 1). Offsets the climatic curve
point
off-set
CH Min.
Sets the minimum supply temperature value in
M1
110
Set-
point
CH Min.
Sets the maximum supply temperature value in
M1
111
Set-
point
Sets the overrun time in seconds of the boiler's
Boiler
circulator during stand-alone operation; cascade
M1
5
Pump
operation determines the boiler's overrun after
Overrun
Sets the value in degrees beyond the set-point at
CH Hys-
M1
7
which the burner switches off for thermoregula-
teresis
CH Hys-
Sets the value in degrees below the set-point at
M1
112
teresis
which the burner switches on again for thermoreg-
Down
Sets the stand-by time before the appliance is
An-
switched on again after it switches off due to
M1
9
ti-cycle
thermoregulation, independently from the supply
Period
temperature dropping below the value indicated in
Par. 10. Parameter valid only in stand-alone mode.
An-
Sets the value in degrees below which the burner
ti-cycle
M1
10
switches on again notwithstanding from the time
Temp.
Diff.
Max.
M1
14
Power
CH
Min.
M1
15
Power
CH/DHW
Design
Defines the max. set-point at the minimum out-
M1
19
Supply
Temp.
Design
Defines the minimum outdoor temperature to
M1
20
Outdoor
which the maximum set-point can be associated
Temp.
Baseline
Defines the minimum set-point at the maximum
M1
21
Supply
outdoor temperature for climatic regulation.
Temp.
Baseline
Defines the maximum minimum outdoor tem-
M1
22
Outdoor
perature to which the minimum set-point can be
Temp.
Description
modes.
mode (Par. 1) = 0.
in presence of mild outdoor temperatures.
heating mode (Par. 1) = 4.
heating mode (Par. 1) = 4.
switch-off due to temperature control.
tion.
ulation.
spent at Par. 9.
Sets the heating's % max. power.
Sets the heating's % min. power.
door temperature for climatic regulation.
for climatic regulation.
associated for climatic regulation.
Access type
U
End user
I
Installer
Range
0 - 5
Par. 23 - Par. 24
Off, - 10 - 10
68 - 122
(20 - 50)
122 - 194
(50 - 90)
0 - 900
0 - 36
(0 - 20)
0 - 36
(0 - 20)
10 - 900
0 - 36
(0 - 20)
50 - 100
1 - 30
86 - 194
(30 - 90)
-52 - 52
(-25 - 25)
86 - 194
(30 - 90)
-32 - 86
(0 - 30)
54
Default
Access
UM
setting
type
0
I
158 (70)
°F (°C)
U
0
I
86 (30)
°F (°C)
I
176 (80)
°F (°C)
I
140
Sec.
I
11 (5)
°F (°C)
I
11 (5)
°F (°C)
I
120
Sec.
I
60.8 (16)
°F (°C)
I
100
%
I
1
%
I
176 (80)
°F (°C)
U
0 (0)
°F (°C)
U
104 (40)
°F (°C)
I
68 (20)
°F (°C)
I
Category
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating
Heating