DISPLAY
"E-1"
Low oil in frypot
Control board overheating
"E-4"
"CPU TOO HOT"
Oil overheating
"E-5"
"FRYER
TOO
HOT"
Temperature probe open
"E-6A"
"FRYER TEMP
SENSOR"
Temperature probe shorted
"E-6B"
"FRYER TEMP
SENSOR"
High limit
"E-10"
"HIGH LIMIT
TRIPPED"
"E-15"
Drain switch
"DRAIN IS OPEN"
Level sensor open
"E-18"
"LEVEL SENSOR
FAILED'
Frypot protection sensor open
"E-19"
"PROTECTION
SENSOR FAILED"
Jan. 2013
CAUSE
Check oil level in JIB (oil reservoir)
Turn switch to OFF position, then turn switch
back to ON; if display shows "E-4", the control
board is getting too hot; check the louvers on each
side of the unit for obstructions
Turn switch to OFF position, then turn switch
back to ON; if display shows "E-5", the heating
circuits and temperature probe should be checked
Turn switch to OFF position, then turn switch
back to ON;if display shows "E-6A", the
temperature probe should be checked
Turn switch to OFF position, then turn switch
back to ON; if display shows "E-6B", the
temperaturechecked
Allow heating elements to cool (15-20 minutes) and
reset high limit by pressing down and releasing raised
side of the switch for the vat that is not operating;
switches are located just to the right of the drain knob;
if high limit does not reset, high limit must be replaced
Make sure drain knob is completely pushed-in; if
E-15 persists, have drain switch checked
Turn switch to OFF position and then back to ON;
if display still indicates a failed sensor, have the
connections checked on the control board; have sensor
checked & replaced if necessory
Turn switch to OFF position and then back to ON;
if display still indicates a failed sensor, have the
connections checked on the control board; have sensor
checked & replaced if necessory