1-3. TROUBLESHOOTING
(CONTINUED)
Problem
Shortening will not drain from
frypot
Filter motor runs but pumps
shortening slowly
Filter switch on but motor does
not run
Motor hums but will not pump
Jan. 2013
Cause
Drain valve clogged with
crumbs
Drain valve will not open
by pulling handle
Pump clogged
Filter line connection loose
Solidified shortening in
lines
Defective switch
Defective motor
Motor thermal protector
tripped
Clogged lines or pump
1-4
Correction
Open valve, force cleaning
brush through drain
Replace Drain valve
Remove pump cover and
clean
Tighten all filter line
connections
Clear all filter lines of
solidified shortening
Check/replace switch per
Filter Switch Section
Check/replace motor
Reset thermal switch on filter
motor
Remove and clean pump and
lines
Replace pump seals, rotor and
rollers