Henny Penny CFE-410 Technical Manual page 36

Open fryer
Table of Contents

Advertisement

Temperature
Spreader
Probe
Sept. 2016
4. Remove the bolts from the five element spreaders. The
element spreaders will now pull off the elements.
5. Remove the brass nuts and washers which secure the ends of
the elements through the frypot wall.
6. Remove the heating elements from the frypot as a group by
lifting the far end and sliding them up and out toward the rear
of the frypot.
Install new o-rings when installing new heating
elements
7. Install new heating elements with the new O-rings terminal
end first at approximately a 45° angle slipping the terminals
through the front wall of the frypot.
8. Replace the brass nuts and washers on the element terminals,
apply 30 foot lbs. of torque when tightening nuts.
9. Evenly space the element spreaders on the sides of the
elements and reinstall bolts. Place the fifth spreader in the
front of the elements as to protect the temperature probe.
10. Replace the high limit bulb holder on the top element.
11. Position the bulb between the top and second element midway
from side to side.
12. Tighten screw that holds the bulb in place.
13. Reconnect the wires to the appropriate terminal as labeled
when they were removed.
14. Replace the front control panel.
15. Connect the power cord to the wall receptacle or close wall
circuit breaker.
3-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfe-420

Table of Contents