Renesas Synergy AE-CLOUD2 User Manual page 45

Application example for cloud connectivity
Table of Contents

Advertisement

Renesas Synergy™ Platform
Amplifier Specifications are listed in the following table.
Table 21 Amplifier Specifications
Item
Frequency Range
Gain
VSWR
Noise Coefficient
DC Voltage
DC Current
Environmental test performance specifications are listed in the following table.
Table 22 Environmental Test Performance Specifications
Normal Temperature
Amplifier Gain
27 dB ± 2.0
≤ 2.0
VSWR
≤ 2.0
Noise Coefficient
Notes: 1. High temperature test: soap in temperature (85ºC) and humidity (95%) chamber for 24-hour and return to
normal temperature (at least for 1-hour) without visual shape change.
2. Low temperature test: soap in temperature (-40ºC) chamber for 24-hour and return to normal temperature (at
least for 1-hour) without visual shape change.
The GPS antenna mechanical dimensions are shown in the following figure.
The antenna environmental requirements are listed in the following table.
Table 23 GPS Antenna Environmental Requirements
Conditions
Working
Storage
7. Certifications
AE-CLOUD2 has been certified to comply with the following standards
7.1 CE
Wireless Coverage:
• Wi-Fi: IEEE 802.11n 2.4G single band
• 2G/EGPRS: 900/1800
• 4G/LTE: B1/3/8/20/28
R12UM0033EU0100 Rev.1.00
Sep 5, 2018
Application Example for Cloud Connectivity (AE-CLOUD2)
Specifications
1575.42 MHz
27 dB
≤2.0
≤2.0 dB
3 to 5V
5 ± 2 mA
Figure 29 GPS Antenna Mechanical Dimensions
Temperature
-35ºC to +80ºC
-40ºC to +85ºC
1
High Temperature
27 dB ± 2.0
≤ 2.0
≤ 2.0
Humidity
0% to 95%
0% to 95%
2
Low Temperature
27 dB ± 2.0
≤ 2.0
≤ 2.0
Page 45 of 48

Advertisement

Table of Contents
loading

Table of Contents