A H 5 0 0 O p e r a t i o n M a n u a l
Error
Description
Code
The communication socket has
16#600C
been used. (SM1109)
16#600D
The RJ45 port is not connected.
An RJ45 port on AH10EN-5A is not
16#600E
connected to a network cable.
The email connection is busy.
16#6100
(SM1113)
The attachment in the email does
16#6104
not exist. (SM1113)
The attachment in the email is
16#6105
oversized. (SM1113)
There is an SMTP server response
16#6107
timeout. (SM1113)
The local communication port set
16#6201
in the TCP socket function is
illegal.
The remote communication port
16#6202
set in the TCP socket function is
illegal.
The device from which the data is
16#6203
sent in the TCP socket function is
illegal.
The transmitted data length set in
16#6204
the TCP socket function is illegal.
The data which is sent through the
16#6205
TCP socket exceeds the device
range.
The device which receives the data
16#6206
in the TCP socket function is
illegal.
The received data length set in the
16#6207
TCP socket function is illegal.
1 2 - 2 6
Solution
1. Check whether the actual data access results in the
use of the same socket.
2. Change the socket number, or retry the socket later.
(This error does not cause the PLC to stop running.
Users can perform the corresponding remedy by
means of the related flag in the program.)
Check the communication cable.
Please check whether AH10EN-5A is connected to a
network cable.
Retry the email connection later. (This error does not
cause the PLC to stop running. Users can perform the
corresponding remedy by means of the related flag in
the program.)
Check whether the attachment exists in the memory
card.
Check the size of the file which is specified as the
attachment. If the size is over 2 MB, the file can not be
specified as the attachment.
1. Check whether the status of the SMTP server is
normal.
2. Retry the sending of the email later. (This error does
not cause the PLC to stop running. Users can perform
the corresponding remedy by means of the related
flag in the program.)
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module in
HWCONFIG again.