INSTALLATIoN
Maintenance
Draining the DHW cylinder
CAUTION Burns
Hot water may escape during draining.
f Close the shut-off valve in the cold water inlet line.
f
f Open the hot water taps on all draw-off points.
f
f Drain the buffer cylinder via the drain valve.
f
Draining the DHW cylinder
Material losses
!
Never use descaling pumps or descaling agents to clean
the cylinder.
f Clean the appliance through the inspection flange.
f
For the torque of the flange screws, see chapter "Specification /
Dimensions and connections".
Replacing the signal anode
f Replace the signal anode if it becomes depleted.
f