Pitco E7 Service, Parts And Schematics page 17

Table of Contents

Advertisement

F
Does the fryer
heat intermittently?
NO
NO
Does the fryer
heat slowly?
YES
Is the fryer
connected to the
proper voltage supply and
is it connected
properly?
Correct the installation.
YES
Are the heating
elements clean?
YES
G
YES
Fryer is functioning
properly.
NO
NO
Perform a weekly cleaning
of the fryer (3.2)
Test the temperature
probe as described in 4.6.
Is the temperature probe
defective?
NO
Test the temperature
set potentiometer as
described in 4.4. Is the
potentionmeter defective?
NO
Test the
temperature control
module as described in
4.5. Is the module
defective?
NO
Check heating elements as
described in 4.3. Replace
heating elements if necessary.
4-12
Replace the
YES
temperature
probe.
YES
Replace the
potentiometer.
Replace the
YES
temperature control
module.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E12E7bE14E14bE14xE18 ... Show all

Table of Contents