Cr - Restore Command Defaults - Teledyne RD Instruments SENTINEL V SELF-CONTAINED Operation Manual

Table of Contents

Advertisement

Sentinel V SC and RT Operation Manual
Saving Data to NV Memory...Done
Reconfiguring Network...Done
Manually Entered Broadcast IP Address:
>cn7
Enable Broadcast Option
Set broadcast address automatically
Enter Broadcast IP Address in dot-decimal format:
Network Directed Broadcast: Enabled
Automatic Broadcast IP Detection: Disabled
Broadcast IP(Manually Set):192.168.0.255
Saving Data to NV Memory...Done
Reconfiguring Network...Done
CN 8
Displays the current CMD port timeout. After the CMD port timeout time has elapsed, the CMD session
will automatically close due to no activity.
>cn8
CMD Port Timeout is 5 minutes
CN 9
Sets a new idle timeout in minutes for the CMD port.
>cn9
Enter Timeout in minutes (1-1440, 0 - No
CMD Port Timeout is set to 5 minutes
Saving Data to NV Memory...Done
CN 10
Displays the basic network information for the physical Ethernet interface.
>cn10
Interface Name: eth0
Carrier: Present
IP: 10.20.230.34
Netmask: 255.255.255.0
CR – Restore Command Defaults
Purpose
Resets the Sentinel V Real-Time command set to factory settings.
Format
CRn
n = 0 (User), 1 (Factory)
Range
Recommended Setting. Use as needed.
Description
The Sentinel V Real-Time automatically stores the last set of commands used in volatile
memory. The Sentinel V Real-Time will continue to be configured from volatile memory
unless it receives a CR command or until the volatile memory loses its power.
(y/n):y
(y/n):n
Timeout):5
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
192.168.0.255
September 2017
Page 203

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SENTINEL V SELF-CONTAINED and is the answer not in the manual?

This manual is also suitable for:

Sentinel v real-time

Table of Contents

Save PDF