Hirschmann MSM20 User Manual

Hirschmann MSM20 User Manual

Mice switch media modules
Hide thumbs Also See for MSM20:

Advertisement

User Manual

Installation
MICE Switch Media Modules
MSM20/22/24/40/42/46/50
Installation MSM20/22/24/40/42/46/50
Technical support
Release 09 11/2016
https://hirschmann-support.belden.eu.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSM20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hirschmann MSM20

  • Page 1: User Manual

    User Manual Installation MICE Switch Media Modules MSM20/22/24/40/42/46/50 Installation MSM20/22/24/40/42/46/50 Technical support Release 09 11/2016 https://hirschmann-support.belden.eu.com...
  • Page 2 In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Hirschmann Automation and Control GmbH Stuttgarter Str.
  • Page 3: Table Of Contents

    About this manual Description General description Device name and product code Slots of the basic device Media modules 1.4.1 Media modules MSM20 1.4.2 Media modules MSM40 1.4.3 PoE-capable media modules MSM22, MSM42 and MSM46 Media module MSM50 MSM24 I/O module...
  • Page 4 Removing an SFP transceiver (optional) Removing a media module 4.2.1 Device variants featuring customer-specific version with the characteristic value HH 4.2.2 Device variants featuring customer-specific version with the characteristic value HX, MX Technical data Further Support Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 5: Safety Instructions

    Certified usage   Use the product only for the application cases described in the Hirschmann product information, including this manual.  Operate the product only according to the technical specifications. See “Technical data” on page 47.  Connect to the product only components suitable for the requirements of the specific application case.
  • Page 6: Grounding The Device

    The following requirements apply without restrictions:  The electrical wires are voltage-free.  The cables used are permitted for the temperature range of the application case.  Relevant for North America: Use 60/75 or 75 °C copper (Cu) wire only. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 7: Supply Voltage

    These can be destroyed, or their life cycles reduced, by the effects of an electrical field or by a charge equalization if the connections are touched. You will find information about electrostatically endangered assemblies in DIN EN 61340-5-1 (2007-08) and DIN EN 61340-5-2 (2007-08). Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 8 In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany www.hirschmann.com The device can be used in the industrial sector.
  • Page 9 Recycling note  After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 10 The following approvals are only in place for the media modules MSM20/24/40/42 in connection with a MSP30/32 basic device: Relevant for Use as Industrial Control Equipment  (according to the Standards UL508 / CSA C22.2 No. 142- 1987) When using the MSP30/32 devices as industrial control equipment the following restrictions apply: Max.
  • Page 11 à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable. Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 12 Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 13 Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 14 Relevant for use in explosive atmospheres (European ATEX  Directive 2014/34/EU) In Ex zone 2, only devices with a corresponding label may be operated. When operating the MSM20/24/40/42 devices in Ex zone 2, the following applies: II 3G Ex nA IIC T4 Gc Ta: −40 °F ...
  • Page 15: About This Manual

    The following manuals are available as PDF files on the Internet on the Hirschmann product pages (www.hirschmann.com):  Basic Configuration user manual  User Manual Installation MSM20/22/24/40/42/46/50  User Manual Installation MSP30/32/40/42  Redundancy Configuration user manual ...
  • Page 16: Description

    Description General description The MSM20/22/24/40/42/46/50 media modules are designed for the special requirements of industrial automation. They meet the relevant technical standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility. You have the option of choosing various media to connect to the terminal devices and other network components: ...
  • Page 17 You will find detailed information on the certificates and declarations declarations applying to your device in a separate overview. See table 3 on page 19. 18 ... 19 Customer-specific Hirschmann standard version Hirschmann Extreme Conditions MAN Extreme Conditions Hardware None configuration Software Entry (Hirschmann Standard) configuration 22 ...
  • Page 18 Application case Certificates and Characteristic value declarations Standard applications ATEX Zone 2 EN 60950-1 EN 61131-2 ISA 12.12.01 – Class I, Div. 2 UL 508 Substation applications IEC 61850-3 IEEE 1613 Navy applications DNVGL Railway applications EN 50121-4 Table 2: Assignment: application cases, certificates and declarations, characteristic values a.
  • Page 19 Assignment: application cases, certificates and declarations, characteristic values a. X = Approval or self-declaration present (X) = Approval or self-declaration present for MSM20/24/40/42 and in preparation for MSM22/46/50 # = Approval or self-declaration only present for MSM20/24/40/42 (#) = Approval or self-declaration in preparation for MSM22/46/50...
  • Page 20: Slots Of The Basic Device

    The maximum data rate of the media modules depends on their slot on the basic device. Some media modules only support data rates up to 10/100 Mbit/s. See “Device name and product code” on page 16. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 21 /100/1000 Mbit/s /100 Mbit/s /100/1000 Mbit/s /100 Mbit/s /100/1000 Mbit/s /100 Mbit/s /100/1000 Mbit/s a. only for twisted pair connections You will find more information about the basic device in the “User Manual Installation MSP30/32/40/42”. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 22: Media Modules

    (read/write)  V.24 data rate: 9,600 Baud Further information on the basic settings of the device can be found in the user manual. 1.4.1 Media modules MSM20 Port 1 (F/O) Port 2 (Twisted Pair) Port 3 (Twisted Pair)
  • Page 23 MSM20-S2S2T1T1... Port 1 (F/O) Port 2 (F/O) Port 3 (F/O) Port 4 (F/O) Table 8: MSM20-S4S4S4S4... Port 1 (Twisted Pair) Port 2 (Twisted Pair) Port 3 (Twisted Pair) Port 4 (Twisted Pair) Table 9: MSM20-T5T5T5T5... Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 24: Media Modules Msm40

    You have the option of alternatively connecting a twisted pair cable via a RJ45 socket or an optical fiber via a SFP transceiver to a combo port. By inserting a SFP transceiver, you deactivate automatically the corresponding twisted pair interface. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 25: Poe-Capable Media Modules Msm22, Msm42 And Msm46

    3-pin terminal block for the PoE supply voltage Table 14: MSM46-T1T1T1T1... The PoE media modules MSM22, MSM42 and MSM46 support Power over Ethernet (PoE) according to IEEE 802.3af and Power over Ethernet Plus (PoE+) according to IEEE 802.3at. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 26 3-pin terminal block. The PoE media module MSM46-T1T1T1T1... thus also functions on MSP devices without internal PoE power supply (MSP30, MSP40). Pin assignment  Figure Case 54 V Table 17: 3-pin terminal block pin assignment Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 27: Media Module Msm50

    Note: On the basic device MSP40/42, the media module slot 1 is coded differently from the other slots. Only MSM50 media modules can be installed on this media module slot. MSM24 I/O module Figure Item Function Input (I) Input Output (O) Output Auxiliary voltage Table 19: MSM24-IOIOIOIO... Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 28: Digital Outputs

    NC contact, channel 1 CENTER-1 Center contact, channel 1 ON-1 NO contact, channel 1 OFF-2 NC contact, channel 2 CENTER-2 Center contact, channel 2 ON-2 NO contact, channel 2 Table 20: Pin assignment of the digital outputs Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 29: Digital Inputs

    Reference potential, channel 3 IN-3 Signal input, channel 3 IN-2-GND Reference potential, channel 2 IN-2 Signal input, channel 2 IN-1-GND Reference potential, channel 1 IN-1 Signal input, channel 1 Table 22: Pin assignment of the digital inputs Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 30: Sfp Transceiver

    (PoE+) according to IEEE 802.3at. The PoE power is supplied via the wire pairs transmitting the signal (phantom voltage). Delivery state: Autonegotiation activated The socket housing is electrically connected with the front panel. The pin assignment corresponds to MDI-X. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 31 (phantom voltage). Delivery state: Autonegotiation activated MSM20 MSM22 Function PoE(PSE) Transmission path Receive path − TD− Transmission path RD− Receive path − Casing: shield Table 24: Pin assignment of 10/100 Mbit/s twisted pair port, M12 socket Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 32 The 100 Mbit/s F/O port allows you to connect network components according to the IEEE 802.3 100BASE-FX standard.  100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode State on delivery:  100 Mbit/s, full duplex Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 33: Display Elements

    Flashing Device is transmitting and/or receiving data Flashes 1 Device detects at least one unauthorized time a MAC address (Port Security Violation) period Table 25: Device status and port status for MSM20 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 34: Msm22, Msm42 And Msm46 Media Modules

    Output budget has been exceeded time a Device has detected a connected powered period device Flashes 3 PoE administrator status deactivated times a period Table 26: Device status and port status for MSM22, MSM42 and MSM46 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 35: Msm24 I/O Module

    Green Lights up The output relay is activated. Yellow Flashes 3 The synchronization of the digital output times a with the assigned input has failed. period Table 27: Device status and I/O status for MSM24 I/O module Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 36: Msm40 Media Modules

    Flashing Device is transmitting and/or receiving data Flashes 1 Device detects at least one unauthorized time a MAC address (Port Security Violation) period Table 28: Device status and port status for MSM40 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 37: Msm50 Media Modules

    Flashing Device is transmitting and/or receiving data Flashes 1 Device detects at least one unauthorized time a MAC address (Port Security Violation) period Table 29: Device status and port status for MSM50 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 38: Installation

    Installation The devices have been developed for practical application in a harsh industrial environment. Hirschmann supplies the media modules ready for operation. Perform the following steps to install and configure the device:  Checking the package contents  Installing media modules ...
  • Page 39: Device Variants Featuring Customer-Specific Version With The Characteristic Value Hh

     Connect the protective conductor according to the pin assignment on the device with the clamp.  Connect the PoE voltage to the 3-pin terminal block. Note: The torque for tightening the terminal block on the device is 3 lb-in (0.34 Nm). Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 40: Device Variants Featuring Customer-Specific Version With The Characteristic Value Hx, Mx

     Remove the protective cap from the slot for the media module on the device.  Mount the media module on the slot.  Fasten the device with the hardware elements provided by screwing to the basic device. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 41: Connecting An I/O Module

    3 - Separate voltage supply for sensor I-GND + 24 V + 24 V − 0 V − 0 V Figure 2: Connection of a sensor with auxiliary voltage supply 1 - Sensor 2 - MSM24 module Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 42: Installing An Sfp Transceiver (Optional)

    MSP30/32/40/42. Installing an SFP transceiver (optional) Only use Hirschmann SFP transceivers.  Remove the protection cap from the SFP transceiver.  Push the transceiver with the lock closed into the slot until it latches in.
  • Page 43: Connecting Data Cables

    “100/1000 Mbit/s F/O port” on page  Connect the data cables according to your requirements. 2.5.5 100 Mbit/s F/O port For further information see “100 Mbit/s F/O port” on page  Connect the data cables according to your requirements. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 44: Maintenance And Service

    Hirschmann is continually working on improving and developing their software. Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (www.hirschmann.com). ...
  • Page 45: Disassembly

    You have the option to remove the media modules while the device is operating. 4.2.1 Device variants featuring customer-specific version with the characteristic value HH Proceed as follows:  Disable the supply voltage.  Additionally with MSM24/MSM46: Disconnect the terminal block.  Disconnect the data cables. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 46: Device Variants Featuring Customer-Specific Version With The Characteristic Value Hx, Mx

    4.2.2 Device variants featuring customer-specific version with the characteristic value HX, MX Proceed as follows:  Disconnect the data cables.  Remove the screws.  Pull the media module out of the slot. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 47: Technical Data

    Temperature of the ambient air at a distance of 2 inches (5 cm) from the device c. Hirschmann recommends to use SFP transceivers with the "EEC" extension. d. Only use SFP transceivers with the “EEC” extension, otherwise the standard temperature range applies.
  • Page 48: Digital Input

    Output voltage range +24 V DC ... +27 V DC Maximum output power 3.0 W Short-circuit protection yes (electronically) Under-voltage deactivation Note: For the pin assignment see “24 V DC auxiliary voltage (AUX)” on page Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 49: Dimension Drawings

    Peak inrush current < 5 A Note: For the pin assignment see “MSM22, MSM42 and MSM46 media modules” on page Dimension drawings  inch 38,2 117,8 4.64 Figure 4: Dimensions for media modules with characteristic value HH Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 50 Figure 5: Dimensions for media module MSM46-T1T1T1T1... with characteristic value HH (with terminal block for external PoE supply voltage) inch 38,2 117,8 4.64 Figure 6: Dimensions for media modules featuring customer-specific version with the characteristic value HX, MX Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 51 EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT Note: The PoE media module MSM46 only complies with the requirements of the EMC directive if a suitable power supply unit is connected. Hirschmann recommends RPS 90/48V power supply units. See “Accessories” on page 56.
  • Page 52 EMC interference Standard Merchant Navy Railway Substation immunity applications applications applications (trackside) Electrostatic discharge EN 61000-4-2 Contact discharge ± 4 kV ± 6 kV ± 6 kV ± 8 kV IEEE C37.90.3 EN 61000-4-2 Air discharge ± 8 kV ± 8 kV ±...
  • Page 53 Media modules MSM2x-T5T5T5T5...HH: 6 kV Note: The PoE media module MSM46 only complies with the requirements of the EMC directive if a suitable power supply unit is connected. Hirschmann recommends RPS 90/48V power supply units. See “Accessories” on page 56.
  • Page 54 Stability Standard Merchant Navy Railway applications Substation applications (trackside) applications IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with 2 Hz ... 13.2 Hz with — 2 Hz ... 9 Hz with 0.14 in. (3.5 mm) 1 mm amplitude 0.12 in.
  • Page 55: Scope Of Delivery

    The order numbers correspond to the product codes of the devices. See “Device name and product code” on page 16. Module Slot Maximum power Power output consumption MSM20 media modules: MSM20-xxT1T1T1... 5.0 W 17.0 Btu (IT)/h MSM20-xxT1T1T1... 4.0 W 14.0 Btu (IT)/h MSM20-xxxxT1T1...
  • Page 56  Only support of the autonegotiation mode including autocrossing. M-SFP-SX/LC 943 014-001 M-SFP-SX/LC EEC 943 896-001 M-SFP-MX/LC EEC 942 108-001 M-SFP-LX/LC 943 015-001 M-SFP-LX/LC EEC 943 897-001 M-SFP-LX+/LC 942 023-001 M-SFP-LX+/ LC EEC 942 024-001 Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
  • Page 57 942 119-001 SFP-GIG-LX/LC 942 196-001 SFP-GIG-LX/LC EEC 942 196-002 a. Further information on certifications can be found on the Internet at the Hirschmann product pages (www.hirschmann.com). Bidirectional Gigabit Ethernet SFP transceiver Order number M-SFP-BIDI Type A LX/LC EEC 943 974-001...
  • Page 58 If your device has a shipping approval according to Germanischer Lloyd or DNVGL, you find the respective approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
  • Page 59: A Further Support

    Further Support Technical Questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com. A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://hirschmann-support.belden.eu.com.

This manual is also suitable for:

Msm24Msm40Msm42Msm46Msm50Msm22

Table of Contents