User Manual Installation MICE Switch Media Modules MSM20/22/24/40/42/46/50 Installation MSM20/22/24/40/42/46/50 Technical support Release 09 11/2016 https://hirschmann-support.belden.eu.com...
Page 2
In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Hirschmann Automation and Control GmbH Stuttgarter Str.
About this manual Description General description Device name and product code Slots of the basic device Media modules 1.4.1 Media modules MSM20 1.4.2 Media modules MSM40 1.4.3 PoE-capable media modules MSM22, MSM42 and MSM46 Media module MSM50 MSM24 I/O module...
Page 4
Removing an SFP transceiver (optional) Removing a media module 4.2.1 Device variants featuring customer-specific version with the characteristic value HH 4.2.2 Device variants featuring customer-specific version with the characteristic value HX, MX Technical data Further Support Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Certified usage Use the product only for the application cases described in the Hirschmann product information, including this manual. Operate the product only according to the technical specifications. See “Technical data” on page 47. Connect to the product only components suitable for the requirements of the specific application case.
The following requirements apply without restrictions: The electrical wires are voltage-free. The cables used are permitted for the temperature range of the application case. Relevant for North America: Use 60/75 or 75 °C copper (Cu) wire only. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
These can be destroyed, or their life cycles reduced, by the effects of an electrical field or by a charge equalization if the connections are touched. You will find information about electrostatically endangered assemblies in DIN EN 61340-5-1 (2007-08) and DIN EN 61340-5-2 (2007-08). Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 8
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany www.hirschmann.com The device can be used in the industrial sector.
Page 9
Recycling note After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 10
The following approvals are only in place for the media modules MSM20/24/40/42 in connection with a MSP30/32 basic device: Relevant for Use as Industrial Control Equipment (according to the Standards UL508 / CSA C22.2 No. 142- 1987) When using the MSP30/32 devices as industrial control equipment the following restrictions apply: Max.
Page 11
à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable. Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 14
Relevant for use in explosive atmospheres (European ATEX Directive 2014/34/EU) In Ex zone 2, only devices with a corresponding label may be operated. When operating the MSM20/24/40/42 devices in Ex zone 2, the following applies: II 3G Ex nA IIC T4 Gc Ta: −40 °F ...
The following manuals are available as PDF files on the Internet on the Hirschmann product pages (www.hirschmann.com): Basic Configuration user manual User Manual Installation MSM20/22/24/40/42/46/50 User Manual Installation MSP30/32/40/42 Redundancy Configuration user manual ...
Description General description The MSM20/22/24/40/42/46/50 media modules are designed for the special requirements of industrial automation. They meet the relevant technical standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility. You have the option of choosing various media to connect to the terminal devices and other network components: ...
Page 17
You will find detailed information on the certificates and declarations declarations applying to your device in a separate overview. See table 3 on page 19. 18 ... 19 Customer-specific Hirschmann standard version Hirschmann Extreme Conditions MAN Extreme Conditions Hardware None configuration Software Entry (Hirschmann Standard) configuration 22 ...
Page 18
Application case Certificates and Characteristic value declarations Standard applications ATEX Zone 2 EN 60950-1 EN 61131-2 ISA 12.12.01 – Class I, Div. 2 UL 508 Substation applications IEC 61850-3 IEEE 1613 Navy applications DNVGL Railway applications EN 50121-4 Table 2: Assignment: application cases, certificates and declarations, characteristic values a.
Page 19
Assignment: application cases, certificates and declarations, characteristic values a. X = Approval or self-declaration present (X) = Approval or self-declaration present for MSM20/24/40/42 and in preparation for MSM22/46/50 # = Approval or self-declaration only present for MSM20/24/40/42 (#) = Approval or self-declaration in preparation for MSM22/46/50...
The maximum data rate of the media modules depends on their slot on the basic device. Some media modules only support data rates up to 10/100 Mbit/s. See “Device name and product code” on page 16. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 21
/100/1000 Mbit/s /100 Mbit/s /100/1000 Mbit/s /100 Mbit/s /100/1000 Mbit/s /100 Mbit/s /100/1000 Mbit/s a. only for twisted pair connections You will find more information about the basic device in the “User Manual Installation MSP30/32/40/42”. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
(read/write) V.24 data rate: 9,600 Baud Further information on the basic settings of the device can be found in the user manual. 1.4.1 Media modules MSM20 Port 1 (F/O) Port 2 (Twisted Pair) Port 3 (Twisted Pair)
Page 23
MSM20-S2S2T1T1... Port 1 (F/O) Port 2 (F/O) Port 3 (F/O) Port 4 (F/O) Table 8: MSM20-S4S4S4S4... Port 1 (Twisted Pair) Port 2 (Twisted Pair) Port 3 (Twisted Pair) Port 4 (Twisted Pair) Table 9: MSM20-T5T5T5T5... Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
You have the option of alternatively connecting a twisted pair cable via a RJ45 socket or an optical fiber via a SFP transceiver to a combo port. By inserting a SFP transceiver, you deactivate automatically the corresponding twisted pair interface. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
3-pin terminal block for the PoE supply voltage Table 14: MSM46-T1T1T1T1... The PoE media modules MSM22, MSM42 and MSM46 support Power over Ethernet (PoE) according to IEEE 802.3af and Power over Ethernet Plus (PoE+) according to IEEE 802.3at. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 26
3-pin terminal block. The PoE media module MSM46-T1T1T1T1... thus also functions on MSP devices without internal PoE power supply (MSP30, MSP40). Pin assignment Figure Case 54 V Table 17: 3-pin terminal block pin assignment Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Note: On the basic device MSP40/42, the media module slot 1 is coded differently from the other slots. Only MSM50 media modules can be installed on this media module slot. MSM24 I/O module Figure Item Function Input (I) Input Output (O) Output Auxiliary voltage Table 19: MSM24-IOIOIOIO... Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
(PoE+) according to IEEE 802.3at. The PoE power is supplied via the wire pairs transmitting the signal (phantom voltage). Delivery state: Autonegotiation activated The socket housing is electrically connected with the front panel. The pin assignment corresponds to MDI-X. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 32
The 100 Mbit/s F/O port allows you to connect network components according to the IEEE 802.3 100BASE-FX standard. 100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode State on delivery: 100 Mbit/s, full duplex Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Flashing Device is transmitting and/or receiving data Flashes 1 Device detects at least one unauthorized time a MAC address (Port Security Violation) period Table 25: Device status and port status for MSM20 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Output budget has been exceeded time a Device has detected a connected powered period device Flashes 3 PoE administrator status deactivated times a period Table 26: Device status and port status for MSM22, MSM42 and MSM46 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Green Lights up The output relay is activated. Yellow Flashes 3 The synchronization of the digital output times a with the assigned input has failed. period Table 27: Device status and I/O status for MSM24 I/O module Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Flashing Device is transmitting and/or receiving data Flashes 1 Device detects at least one unauthorized time a MAC address (Port Security Violation) period Table 28: Device status and port status for MSM40 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Flashing Device is transmitting and/or receiving data Flashes 1 Device detects at least one unauthorized time a MAC address (Port Security Violation) period Table 29: Device status and port status for MSM50 media modules Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Installation The devices have been developed for practical application in a harsh industrial environment. Hirschmann supplies the media modules ready for operation. Perform the following steps to install and configure the device: Checking the package contents Installing media modules ...
Connect the protective conductor according to the pin assignment on the device with the clamp. Connect the PoE voltage to the 3-pin terminal block. Note: The torque for tightening the terminal block on the device is 3 lb-in (0.34 Nm). Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Remove the protective cap from the slot for the media module on the device. Mount the media module on the slot. Fasten the device with the hardware elements provided by screwing to the basic device. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
3 - Separate voltage supply for sensor I-GND + 24 V + 24 V − 0 V − 0 V Figure 2: Connection of a sensor with auxiliary voltage supply 1 - Sensor 2 - MSM24 module Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
MSP30/32/40/42. Installing an SFP transceiver (optional) Only use Hirschmann SFP transceivers. Remove the protection cap from the SFP transceiver. Push the transceiver with the lock closed into the slot until it latches in.
“100/1000 Mbit/s F/O port” on page Connect the data cables according to your requirements. 2.5.5 100 Mbit/s F/O port For further information see “100 Mbit/s F/O port” on page Connect the data cables according to your requirements. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Hirschmann is continually working on improving and developing their software. Check regularly whether there is an updated version of the software that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (www.hirschmann.com). ...
You have the option to remove the media modules while the device is operating. 4.2.1 Device variants featuring customer-specific version with the characteristic value HH Proceed as follows: Disable the supply voltage. Additionally with MSM24/MSM46: Disconnect the terminal block. Disconnect the data cables. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
4.2.2 Device variants featuring customer-specific version with the characteristic value HX, MX Proceed as follows: Disconnect the data cables. Remove the screws. Pull the media module out of the slot. Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Temperature of the ambient air at a distance of 2 inches (5 cm) from the device c. Hirschmann recommends to use SFP transceivers with the "EEC" extension. d. Only use SFP transceivers with the “EEC” extension, otherwise the standard temperature range applies.
Output voltage range +24 V DC ... +27 V DC Maximum output power 3.0 W Short-circuit protection yes (electronically) Under-voltage deactivation Note: For the pin assignment see “24 V DC auxiliary voltage (AUX)” on page Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Peak inrush current < 5 A Note: For the pin assignment see “MSM22, MSM42 and MSM46 media modules” on page Dimension drawings inch 38,2 117,8 4.64 Figure 4: Dimensions for media modules with characteristic value HH Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 50
Figure 5: Dimensions for media module MSM46-T1T1T1T1... with characteristic value HH (with terminal block for external PoE supply voltage) inch 38,2 117,8 4.64 Figure 6: Dimensions for media modules featuring customer-specific version with the characteristic value HX, MX Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 51
EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT Note: The PoE media module MSM46 only complies with the requirements of the EMC directive if a suitable power supply unit is connected. Hirschmann recommends RPS 90/48V power supply units. See “Accessories” on page 56.
Page 52
EMC interference Standard Merchant Navy Railway Substation immunity applications applications applications (trackside) Electrostatic discharge EN 61000-4-2 Contact discharge ± 4 kV ± 6 kV ± 6 kV ± 8 kV IEEE C37.90.3 EN 61000-4-2 Air discharge ± 8 kV ± 8 kV ±...
Page 53
Media modules MSM2x-T5T5T5T5...HH: 6 kV Note: The PoE media module MSM46 only complies with the requirements of the EMC directive if a suitable power supply unit is connected. Hirschmann recommends RPS 90/48V power supply units. See “Accessories” on page 56.
Page 54
Stability Standard Merchant Navy Railway applications Substation applications (trackside) applications IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with 2 Hz ... 13.2 Hz with — 2 Hz ... 9 Hz with 0.14 in. (3.5 mm) 1 mm amplitude 0.12 in.
The order numbers correspond to the product codes of the devices. See “Device name and product code” on page 16. Module Slot Maximum power Power output consumption MSM20 media modules: MSM20-xxT1T1T1... 5.0 W 17.0 Btu (IT)/h MSM20-xxT1T1T1... 4.0 W 14.0 Btu (IT)/h MSM20-xxxxT1T1...
Page 56
Only support of the autonegotiation mode including autocrossing. M-SFP-SX/LC 943 014-001 M-SFP-SX/LC EEC 943 896-001 M-SFP-MX/LC EEC 942 108-001 M-SFP-LX/LC 943 015-001 M-SFP-LX/LC EEC 943 897-001 M-SFP-LX+/LC 942 023-001 M-SFP-LX+/ LC EEC 942 024-001 Installation MSM20/22/24/40/42/46/50 Release 09 11/2016...
Page 57
942 119-001 SFP-GIG-LX/LC 942 196-001 SFP-GIG-LX/LC EEC 942 196-002 a. Further information on certifications can be found on the Internet at the Hirschmann product pages (www.hirschmann.com). Bidirectional Gigabit Ethernet SFP transceiver Order number M-SFP-BIDI Type A LX/LC EEC 943 974-001...
Page 58
If your device has a shipping approval according to Germanischer Lloyd or DNVGL, you find the respective approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
Further Support Technical Questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com. A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://hirschmann-support.belden.eu.com.
Need help?
Do you have a question about the MSM20 and is the answer not in the manual?
Questions and answers