User Manual Installation MICE Switch Power MSP30/32 MSP30/MSP32-0804... MSP30/MSP32-1604... MSP30/MSP32-2404... Installation MSP30/32 Technical support Release 04 07/2014 https://hirschmann-support.belden.eu.com...
Page 2
In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str.
Installing and grounding the device 2.3.1 Installing the device onto the DIN rail 2.3.2 Grounding the device Connecting the terminal blocks 2.4.1 Working voltage with the characteristic value C 2.4.2 Working voltage with the characteristic value P Installation MSP30/32 Release 04 07/2014...
Page 4
2.4.3 Signal contact Connecting the ferrite Installing terminal blocks, switching on the working voltage Installing media modules Basic Settings Upgrading Software Maintenance and service Disassembly Removing a media module Removing the device Technical data Further Support Installation MSP30/32 Release 04 07/2014...
Never start operation with damaged components. The device does not contain any service components. If the device is not functioning correctly, or if it is damaged, turn off the power supply and return the device to Hirschmann for inspection. WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually.
Intended usage Use the product only for the application cases described in the Hirschmann product information, including this manual. Operate the product only according to the technical specifications. See “Technical data” on page 45. Connect to the product only components suitable for the requirements of the specific application case.
If you are operating the device in a living area or office environment, only operate it in switch cabinets with fire protection characteristics in accordance with EN 60950-1. Installation MSP30/32 Release 04 07/2014...
Page 8
In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538 The device can be used in the industrial sector.
Page 9
(according to the Standards UL508 / CSA C22.2 No. 142- 1987) When using the MSP30/32 devices as industrial control equipment the following restrictions apply: Max. surrounding air temperature: +60 °C (... to apply for operating temperature characteristic values S, T or E) Use Copper Conductors only.
Page 10
Note: For information about the position on the device see “View from above” on page - For installation and use of the MSM20/24/40/42 Media Modules- refer to the document "USER MANUAL Installation" document to the Media Modules MSM20/24/40/42. Installation MSP30/32 Release 04 07/2014...
Page 13
Relevant for use in Ex Zone 2 according to ATEX 95 (European directive 94/9/EC) In Ex zone 2, only devices with a corresponding label may be operated. When operating the MSP30/32 devices in Ex zone 2, the following applies: II 3G Ex nA IIC T4 Gc Ta: –40 °C ...
Page 14
Recycling note After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country. Installation MSP30/32 Release 04 07/2014...
The following manuals are available as PDF files on the CD/DVD supplied: Basic Configuration user manual User Manual Installation MSM20/24/40/42 User Manual Installation MSP30/32 Redundancy Configuration user manual Command Line Interface user manual Reference manual for the graphical user interface...
Transmission speed Certifications The MSP30/32 devices are designed for the special requirements of indus- trial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also long- term reliability and flexibility.
14 ... 15 Certificates and Note: You will find detailed information on the certificates and declarations declarations applying to your device in a separate overview. See table 2 on page 19. Table 1: Device name and product code Installation MSP30/32 Release 04 07/2014...
Page 18
Reserved Unicast Routing Unicast + Multicast Routing 18 ... 19 Customer-specific Hirschmann standard version Software configuration E Entry (Hirschmann standard configuration) 21 ... 22 Software level HiOS Layer 2 Advanced 23 ... 27 Software version 02.0 Software version 02.0 XX.X...
Page 19
Application case Certificates and Characteristic value declarations Standard applications ATEX Zone 2 EN 60950-1 EN 61131-2 ISA 12.12.01 – Class I, Div. 2 UL 508 Substation applications IEC 61850-3 IEEE 1613 Navy applications Railway applications EN 50121-4 Table 2: Assignment: application cases, certificates and declarations, characteristic values...
Page 20
Figure 1: Example of a device name:MSP32-24040SPZ999HHE2A02.0...
Slot 3 for media modules Locking gate for removing the device Backplane (switch basic module MSP30/32) Power (switch basic module MSP30/32) module Grounding screw Terminal block, V.24 port, USB port, signal contacts Table 4: Front view (using example MSP30/32-0804...) Installation MSP30/32 Release 04 07/2014...
Power supply input for redundant power supply 4-pin terminal block Connection for 2 digital inputs USB interface In software version 02.0, the device does not support the ACA21. Table 5: View from below (using example MSP30/32-0804...) Installation MSP30/32 Release 04 07/2014...
Slot 2 for media modules Slot 1 for media modules Backplane (switch basic module MSP30/32) Power module (switch basic module MSP30/32) Knurled screw Slot for the SD card Table 6: View from above (using example MSP30/32-0804...) Installation MSP30/32 Release 04 07/2014...
You will find the arrangement and sequence of the slots in the basic module in the following overview: MSP30/32-0804... 1 10 /100/1000 Mbit/s 2 10 /100 Mbit/s 3 10 /100 Mbit/s a. solely for twisted-pair connections Installation MSP30/32 Release 04 07/2014...
Page 26
Mbit/s /100 Mbit/s /100 Mbit/s /100 Mbit/s /100 Mbit/s /100 Mbit/s /100 Mbit/s a. solely for twisted-pair connections You will find more information on the media modules in the “User Manual for Installation of MSM20/24/40/42”. Installation MSP30/32 Release 04 07/2014...
After the working voltage is set up, the software starts and initializes itself. Afterwards, the device performs a self-test. During this process, various LEDs light up. 1.7.1 Device state These LEDs provide information about conditions which affect the operation of the whole device. Status Power Installation MSP30/32 Release 04 07/2014...
LED display element for input — None Low level input voltage Green Lights up High level input voltage LED display element for input — None Low level input voltage Green Lights up High level input voltage Installation MSP30/32 Release 04 07/2014...
Pin assignment of the V.24 interface Note: For information about the position on the device see “View from below” on page You find the order number for the terminal cable, which is available as acces- sory, under “Accessories” on page Installation MSP30/32 Release 04 07/2014...
On the front of the device there is an LED display that informs you about the status of the interface. Only use Hirschmann SD cards. 1.8.3 USB interface The USB interface allows you to connect the AutoConfiguration Adapter ACA21 storage medium.
Input 2 (I2) 3 IN-2 Signal input, channel 2 IN-2-GND Reference potential, channel 2 Table 11: Pin assignment of the input interface Note: For information about the position on the device see “View from below” on page Installation MSP30/32 Release 04 07/2014...
Installation The devices have been developed for practical application in a harsh indus- trial environment. Hirschmann supplies the device ready for operation. The following steps should be performed to install and configure a device: Checking the package contents ...
Install the device on a horizontally mounted 1.38 inch (35 mm) DIN rail in accordance with DIN EN 60715. Insert the upper snap-in guide of the device into the DIN rail and press the device down against the DIN rail until it snaps into place. Installation MSP30/32 Release 04 07/2014...
Both power supply unit variants have a function ground. Ground the device via the ground screw. Note: For information about the position on the device see “View from below” on page Installation MSP30/32 Release 04 07/2014...
Working voltage with the characteristic value C You have the option of supplying the working voltage redundantly, without load distribution. Both working voltage inputs are uncoupled. Table 12: Operating voltage characteristic value C: two 4-pin terminal blocks Installation MSP30/32 Release 04 07/2014...
DC voltage Voltage range DC incl. Minus terminal of the maximum tolerances: working voltage 45 V ... 57 V Table 15: Operating voltage characteristic value P: type and specification of the supply voltage, connections Installation MSP30/32 Release 04 07/2014...
See “General technical data” on page 45. Connect the signal contact wires with the connectors of the terminal block. Connecting the ferrite Note: Applies exclusively for MSP30/32-0804 with certifications for marine applications. To adhere to EMC conformity, you connect the ferrite supplied to the voltage input via the voltage supply line.
4.5 lb-in (0.51 Nm). The torque for tightening the signal contact and input terminal block on the device is 3 lb-in (0.34 Nm). Use screws to secure the connectors to the device. Enable the working voltage. Installation MSP30/32 Release 04 07/2014...
Installing media modules Hirschmann supplies the media modules ready for operation. You have the option to mount the media modules while the device is oper- ating. Proceed as follows: Remove the protective cap from the slot of the basic module.
The temperature displayed in the CLI and the GUI is the internal tempera- ture of the device. It is up to 68 °F (20 °C) higher than the ambient temperature. This depends on the configuration of your device. Installation MSP30/32 Release 04 07/2014...
Upgrading Software The upgrade options for your MSP30/32 device depend on the software level of the device. See “Device name and product code” on page 17. Note: For software version 04.0 or higher, “HiOS” is available as a common software image for all software levels.
Hirschmann are continually working on improving and developing their software. Check regularly whether there is an updated version of the soft- ware that provides you with additional benefits. You find information and software downloads on the Hirschmann product pages on the Internet (www.hirschmann.com). ...
Use the screwdriver to carefully lever the female multipoint connector away from the media module and pull the media module out of the slot. Figure 5: Removing a media module Note: For information about the position on the device see “Front view” on page Installation MSP30/32 Release 04 07/2014...
Insert a screwdriver horizontally below the housing into the locking gate. Without tilting the screwdriver, pull the locking gate down and tilt the device upwards. Figure 6: Removing the basic module from the DIN rail Installation MSP30/32 Release 04 07/2014...
> 10 ms at 20.4 V DC (applies only to the basic module) Overload current protection at Non-replaceable fuse input Back-up fuse Nominal rating: 6.3 A Characteristic: slow blow Peak inrush current < 5 A Installation MSP30/32 Release 04 07/2014...
Page 46
Temperature of the ambient air at a distance of 2 inches (5 cm) from the device b. Hirschmann recommends to use SFP transceivers with the "EEC" extension. c. Only use SFP transceivers with the “EEC” extension, otherwise the standard temperature range applies.
Dimension drawings inch 236,6 Figure 7: Dimensions of device variants MSP30/32-0804... See “Device name and product code” on page 17. Installation MSP30/32 Release 04 07/2014...
Page 48
313,8 12.35 Figure 8: Dimensions of device variants MSP30/32-1604... See “Device name and product code” on page 17. Installation MSP30/32 Release 04 07/2014...
Page 49
15.39 Figure 9: Dimensions of device variants MSP30/32-2404... See “Device name and product code” on page 17. Installation MSP30/32 Release 04 07/2014...
Page 50
EMC and immunity EMC interference emis- Standard Merchant Navy Railway applica- Substation sion applications tions applications (trackside) Radiated emission EN 55022 Class A Class A Class A Class A GL Guidelines — EMC 1 — — FCC 47 CFR Part 15 Class A Class A Class A...
Page 51
EMC interference immu- Standard Merchant Navy Railway applica- Substation nity applications tions applications (trackside) Electrostatic discharge EN 61000-4-2 Contact discharge ± 4 kV ± 6 kV ± 6 kV ± 8 kV IEEE C37.90.3 EN 61000-4-2 Air discharge ± 8 kV ±...
Page 52
EMC interference immu- Standard Merchant Navy Railway applica- Substation nity applications tions applications (trackside) Damped vibration – DC supply connection EN 61000-4-12 line/ground — — — 2.5 kV IEEE C37.90.1 EN 61000-4-12 line/line — — — 1 kV IEEE C37.90.1 Damped oscillation - data line EN 61000-4-12 line/ground...
Page 53
Stability Standard applications Merchant Navy Railway appli- Substation applications cations (trackside) IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with 0.14 in. 2 Hz ... 13.2 Hz — 2 Hz ... 9 Hz with (3.5 mm) amplitude with 0.12 in.
943 974-002 M-SFP-BIDI Type A LH/LC EEC 943 975-001 M-SFP-BIDI Type B LH/LC EEC 943 975-002 M-SFP-BIDI Bundle LX/LC EEC (type A + B) 943 974-101 M-SFP-BIDI Bundle LH/LC EEC (type A + B) 943 975-101 Installation MSP30/32 Release 04 07/2014...
Page 55
M-FAST SFP-LH/LC EEC 943 948-001 Note: Some products recommended as accessories do not support the entire temperature range specified for the device and can thus restrict the possible range of usage for the overall system. Installation MSP30/32 Release 04 07/2014...
Page 56
If your device has a shipping approval according to Germanischer Lloyd, you find the approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
Further Support Technical Questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com Contact our support at https://hirschmann-support.belden.eu.com You can contact us in the EMEA region at ...