6. Installing the drop cable and LPU

Installing and grounding the main drop cable

Follow all instructions provided by the hoisting grip manufacturer. Failure to
do so may result in injury or death.
To install and ground the main drop cable, proceed as follows:
1
Hoist the main drop cable up to the ODU using the hoisting grip and a hoist line.
When the cable is in position and the grip handle is fastened to the supporting
structure, remove the hoist line.
2
Connect the top end of the main drop cable to the ODU (PIDU+ port), as
described in
3
Lay the main drop cable as far as the building entry point, ensuring there is
enough length to extend through the wall of the building to the LPU.
4
Attach the main drop cable to the supporting structure using site approved
methods.
5
Ground the drop cable to the supporting structure at the points shown in
tower installation
procedure in

Connecting an RJ45 and gland to an ODU or LPU

To connect a drop cable with a gland to a unit (LPU or ODU), proceed as follows:
1
Insert the RJ45 plug into the socket in the unit, making sure that the locking tab
snaps home.
2
Support the drop cable and gently hand screw the gland body into the unit until the
O ring seal is flush to the unit body.
Do not fit the back shell prior to securing the gland body.
phn-2508_005v000 (Mar 2013)
Connecting an RJ45 and gland to an ODU or LPU
on page
12
or
Making a drop cable ground point
Wall installation
on page 13. Follow the
on page 23.
PTP 500 Installation Guide
on page 21.
Mast or
Page 21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 300 series

Table of Contents