4 Installation
4.3

Required minimum clearances

E
D
C
Fig. 4.2 Installation clearances
Key
A At least 50 mm
B At least 50 mm
C At least 120 mm
D At least 130 mm
E Maximum 22 mm
The bottom section of the unit (D) must be level with the
unit's bearing area on the wall; to a height of at least
130 mm. Any possible wall offset (e.g. due to tiles) must
not exceed 22 mm (E). The distance to the floor must be
at least 120 mm (C). The distance above, to the left and
to the right of the unit must be at least 50 mm.
8
A
B
B
C
Installation instructions for the electronicVED plus electric instantaneous water heater 0020149585_00
4.4

Mounting the unit to the wall

4.4.1

Unit and connection dimensions

35
35
100
Fig. 4.3 Unit dimensions
Key
1
Upper anti-spray-water sleeve
2 Central attachment
3 Display
4 Hot water connection R 1/2
5 Cold water connection R 1/2
6 Lower anti-spray-water sleeve
R Outside thread R 1/2
1
3
Fig. 4.4 Connection dimensions
Key
1
Installation plate
2 Cold water connection
3 Hot water connection
19
16
5
100
240
85
85
1
2
1
2
3
4
5
6