Installation Site; Required Minimum Clearances - Vaillant VED Operating And Installation Instructions

Electric instantaneous water heater
Table of Contents

Advertisement

No. Quantity Name
1
1
VED electric instantaneous water heater
2
1
Operating and installation instructions
Box containing fixings (2 bolts, 2 rawl plugs,
3
1
1 seal, 1 special fixing screw)
Cold water connection piece R 1/2 with a cold
4
1
water stop valve
Hot water connection piece R 1/2 supplied in the
5
1
box
6
1
Installation plate
7
1
Installation template
Tab. 4.1 Scope of delivery
The VED electric instantaneous water heater is com-
pletely pre-assembled. Once the unit has been fitted to
the wall, only the water and electrical installation needs
to be completed.
4.2

Installation site

b
Caution.
Risk of frost damage to the unit.
If a VED electric instantaneous water heater
is placed out of operation for a relatively long
period of time in an unheated room in cold
weather, the water in the unit and pipes may
freeze. This results in damage to the unit.
> Install the unit in a permanently frost-free
room.
i
The VED electric instantaneous water heater
meets the current safety regulations for pro-
tected zone 1 and can therefore also be
installed above the bath or in a shower area.
> Wherever possible, install the unit near the draw-off
point that will be most used.
Installation instructions for VED electric instantaneous water heater 0020149586_00
4.3

Required minimum clearances

E
D
C
Fig. 4.2 Installation clearances
Key
A At least 50 mm
B At least 50 mm
C At least 120 mm
D At least 130 mm
E Maximum 22 mm
The bottom section of the unit (D) must be level with the
unit's bearing area on the wall; to a height of at least
130 mm. Any possible wall offset (e.g. due to tiles) must
not exceed 22 mm (E). The distance to the floor must be
at least 120 mm (C). The distance above, to the left and
to the right of the unit must be at least 50 mm.
Installation 4
A
B
B
C
7