10 Technical data
Unit type
Art. no.
For supplying
Design
Configuration
Capacity
Dimensions width
Height
Depth
Weight when filled with water
Performance characteristics
Water inlet temperature
Switch-on water volume
Switch-off water volume
Switch-on flow pressure
Max. water flow rate
Rated overpressure
Rated output* (T of max. 38 K)
Minimum water resistance at 15 °C
Measuring voltage
Safety
Level of protection
Tab. 10.1 Technical data
1) = closed unit (pressure resistant)
* at 380/400 V
Installation instructions for the electronicVED plus electric instantaneous water heater 0020149585_00
VED E 18/7 P
Unit
0010007723
one or more draw-off points
Appliance for wall-mounted installation
Bare wire heating coil
l
0.4
mm
240
mm
481
mm
100
kg
4.4
Electronically regulated output
°C
l/min
l/min
MPa
0.015
l/min
6
MPa
kW
15.7/18.0
cm
900
3/PE~ 380/400 V; 50 Hz
Complies with German and Austrian safety regulations; radio-shielded; does not
interact with the mains supply
IP 25 = sprayed-water protection
VED E 21/7 P
VED E 24/7 P
0010007724
0010007725
1)
1...60
3
2.5
7
8
1
18.5/21.0
21.0/24.0
Technical data 10
VED E 27/7 P
0010007726
1...25
9
23.7/27.0