4
Installation
a
Risk of death!
Risk of death due to improper installation!
All work involved in the installation, start-up,
maintenance and repair of the electronicVED
plus electric instantaneous water heater must
only be carried out by a recognised compe-
tent person, who also assumes the responsi-
bility for installing the unit properly and
commissioning it for the first time. The
electronicVED plus electric instantaneous
water heater must be installed in strict com-
pliance with these installation instructions.
i
Flush the cold water pipes thoroughly before
installation.
4.1
Scope of delivery
> Check that the scope of delivery is complete (see
tab. 4.1).
Fixing points
170
Top electrical connection
Mounting plate
Installation template
for VED
As required:
Additional fixing point for back wall
Bottom
electrical connection
100
Hot water connection
Cold water connection
6
Fig. 4.1 Scope of delivery
Installation instructions for the electronicVED plus electric instantaneous water heater 0020149585_00
7
2
4
3
5
No. Quantity Name
1
1
2
1
3
1
4
1
5
1
6
1
7
1
Tab. 4.1 Scope of delivery
The electronicVED plus electric instantaneous water
heater is completely pre-assembled. Once the unit has
been fitted to the wall, only the water and electrical
installation needs to be completed.
4.2

Installation site

b
Caution.
Risk of frost damage to the unit.
If an electronicVED plus electric instantane-
1
ous water heater is placed out of operation
for a relatively long period of time in an
unheated room in cold weather, the water in
the unit and pipes may freeze. This results in
damage to the unit.
> Install the unit in a permanently frost-free
room.
i
The electronicVED plus electric instantaneous
water heater meets the current safety regula-
tions for protected zone 1 and can therefore
also be installed above the bath or in a
shower area.
> Wherever possible, install the unit near the draw-off
point that will be most used.

Installation 4

electronicVED plus electric instantaneous water
heater
Operating and installation instructions
Box containing fixings (2 bolts, 2 rawl plugs,
1 seal, 1 special fixing screw)
Cold water connection piece R 1/2 with a cold
water stop valve
Hot water connection piece R 1/2 supplied in the
box
Installation plate
Installation template
7