Vega VEGAPULS 63 Operating Instructions Manual page 48

Radar sensor for continuous level measurement of liquids two-wire 4...20 ma/hart
Hide thumbs Also See for VEGAPULS 63:
Table of Contents

Advertisement

6 Set up with the display and adjustment module
Setup - Min. adjustment
48
Fig. 33: Parameterisation example, Min./max. adjustment
1
Min. level = max. measuring distance
2
Max. level = min. measuring distance
3
Reference plane
If these values are not known, an adjustment with the distances of e.g.
10 % and 90 % is possible. Starting point for these distance specifica-
tions is always the sealing surface of the thread or flange. You can find
further specifications on the reference plane in the chapters "Mount-
ing instructions" and "Technical data". The actual level is calculated
on the basis of these settings.
The actual product level during this adjustment is not important,
because the min./max. adjustment is always carried out without
changing the product level. These settings can be made ahead of
time without the instrument having to be installed.
Proceed as follows:
1. Select the menu item "Setup" with [->] and confirm with [OK].
Now select with [->] the menu item "Min. adjustment" and confirm
with [OK].
2. Edit the percentage value with [OK] and set the cursor to the
requested position with [->].
3. Set the requested percentage value with [+] and save with [OK].
The cursor jumps now to the distance value.
VEGAPULS 63 • Two-wire 4 ... 20 mA/HART
3
2
100%
1
0%