Download Print this page

Troubleshooting - BEA LZR-I30 Manual

Laser scanners for industrial doors, max. detection range of 30 ft x 30 ft
Hide thumbs Also See for LZR-I30:

Advertisement

TROUBLESHOOTING

No blue LED
Only the blue LED is
on.
The detection LED
remains green.
The detection LED
remains red.
The orange LED is
flashing and the
detection LEDs are
red.
The orange LED
is on.
The sensor does
not respond to the
remote control.
The sensor does not
unlock.
Page 10 of 12
Page 10 of 12
There is no power.
The polarity of the power
supply is inverted.
All LEDs have been de-
activated by remote control.
The test input is not
connected.
The detection field is too
small or deactivated.
The object size is too small.
Someone or something is
in the detection field.
The field is touching the
floor, the wall, the door, an
object or a person which
leads to detection.
No background (reference
point) is found.
The sensor is masked.
The power supply voltage is
exceeding the acceptable
limits.
The sensor exceeds its
temperature limits.
Internal error
30 minutes after last use of
the remote control, the
sensor locks the access to
the remote control session.
The batteries in the remote
control are not installed
properly or dead.
The remote control is badly
pointed.
A reflective object is in close
proximity to the sensor.
You have to enter an access
code or the wrong code was
entered.
1
Check cable and connexion.
Check the polarity of the power supply.
1
1
Activate the LEDs by remote control.
1
Check wiring.
The BLUE and BLUE/WHITE cable have to be
connected to the test input or the power supply.
1
Check the size of the fields.
2
Launch a teach-in.
1
Decrease the min. object size.
1
Step out of the field and/or remove the any
object(s) from the field and launch a teach in.
1
Activate the 3 red beams and check if the
position of the sensor is correct.
If not, adjust the hex screws.
2
Verify the field size.
3
Launch a teach-in.
1
Check the position of the sensor.
Check the mounting side setting.
2
If there is no background, set the mounting side
to value 3 to 5.
Launch a new teach-in.
3
1
Verify and clean the front screens
with a damp cloth.
1
Check the power supply voltage.
1
Verify the outside temperature where the sensor
is installed. Eventually protect the sensor from
sunlight using a cover.
1
Wait a few seconds.
If the LED remains ON, reset the power supply.
If the LED turns on again, replace the sensor.
1
Cut and restore power supply.
The remote control session is accessible again
during 30 minutes.
1
Verify or replace the batteries.
1
Point the remote control towards the sensor, but
with a slight angle. The RC should not be
pointed in a right angle in front of the sensor.
Avoid highly reflective material in proximity to
1
the sensor.
1
Cut and restore power supply.
No code is required to unlock during the first
minute after powering.
75.5667.10 LZR-I30 20161212
75.5667.10 LZR-I30 20161212

Advertisement