MGE UPS Systems Galaxy PW Installation Manual

MGE UPS Systems Galaxy PW Installation Manual

20 - 200 kva battery and auxiliary cubicles supplied empty
Hide thumbs Also See for Galaxy PW:

Advertisement

www.mgeups.com
MGE UPS SYSTEMS
Galaxy PW™
20 - 200 kVA
Battery and
auxiliary cubicles
supplied empty
Installation manual
E-51028233XU/BF
- Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Galaxy PW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MGE UPS Systems Galaxy PW

  • Page 1 MGE UPS SYSTEMS Galaxy PW™ 20 - 200 kVA Battery and auxiliary cubicles supplied empty Installation manual - Page 1 E-51028233XU/BF...
  • Page 2 Page 2 - E-51028233XU/BF...
  • Page 3: Table Of Contents

    Mechanical characteristics ..................10 Views of cubicles ...................... 10 All Galaxy PW products are protected by patents. They implement original MGE UPS SYSTEMS technology not available to other manufacturers. To take into account evolving standards and technology, equipment may be modified without notice. Indications concerning technical characteristics and dimensions are not binding unless confirmed by MGE UPS SYSTEMS .
  • Page 4: Introduction

    MGE UPS SYSTEMS or batteries depth as Galaxy PW cubicles, of user delivered separately for transportation ancillary equipment used in conjunction reasons; with a Galaxy PW UPS.
  • Page 5: Battery Cubicles

    Mechanical characteristics The battery cubicles are installed to the battery outside cubicle max. weight inside dimensions in mm left of the Galaxy PW UPS rectifier- cubicle width dimensions in mm weight of battery (see cubicle views) inverter cubicle. The cubicles are...
  • Page 6: Views Of Cubicles

    Battery cubicles (cont.) Views of cubicles Example of a cubicle containing a battery circuit breaker. Cubicles not containing a battery circuit breaker have an additional row of cells at the bottom. front view (715 or 1015 mm wide cubicles) position shelves as required optional circuit breaker QF1...
  • Page 7 Battery cubicles (cont.) cross-section AA (715 or 1015 mm wide cubicles) air outlet (1900 mm high cubicle) front rear shelf support cross-member shelf air outlet (1400 mm high cubicle) air inlet connector XR1 optional battery circuit breaker QF1 cables tied to air inlet the grating connection...
  • Page 8: Installation

    Battery cubicles (cont.) cross-section BB (715 or 1015 mm wide cubicles) rear bottom grating opening for feeding opening for feeding cables via the bottom cables via the bottom securing of battery circuit breaker kit by 2 screws earthing connection front battery circuit breaker (optional) support plate for...
  • Page 9: Connections

    UPS. end of the shelves; Details of these connections are given the cables providing connections in Galaxy PW installation manual n° between cubicles are routed via the 51028231XU, section "connection of bottom: Media Contacts 11 standard auxiliary via an opening in a false floor or circuits".
  • Page 10: Auxiliary Cubicle

    Auxiliary cubicle Mechanical characteristics cubicle weight auxiliary cubicle outside dimensions inside dimensions in mm in kg width in mm in mm (see cubicle views) 1400 ± 10 825 1170 1900 ± 10 825 1670 1400 ± 10 825 1015 1170 1900 ±...
  • Page 11 Auxiliary cubicle (cont.) cross-section AA connection via the top (see top view) air outlet (1900 mm high cubicle, see top view) earthing connection (connection via the top) front rear air outlet (1400 mm high cubicle) air inlet earthing connection (connection via the bottom) air inlet connection via the bottom (see cross-section BB)
  • Page 12 Auxiliary cubicle (cont.) top view (1900 mm high cubicle) rear cable entry via the top: 460 x 204 mm opening and cable gland plate ventilation grate front Fig. 8 cross-section BB rear front Fig. 9 Page 12 - E-51028233XU/BF...

Table of Contents