Menu Tree - Bindicator SonoTracker Ultrasonic Liquid Level Installation & Operation Manual

Can monitor up to a total of 8 transducers of various frequencies, accommodating multiple vessels of different heights and shapes.
Table of Contents

Advertisement

SonoTracker Series
10 Display
3. Scroll with the arrow keys to the 90 Service Menu option. Press Enter. The display shows:
Service Menu
91 Access
4. Press Enter. Then select User, press Enter. Use the keypad to enter a one-, two-, three-, or four-digit
number. Press the Enter Key when done entering the number. The display flashes a message
acknowledging the entry and returns.
Note: Record the access code and store it in a safe place. If misplaced, call Bindicator for instructions
to bypass the code.
Once the number is entered, you have access to all functions and hidden menus that require the code,
while you remain within the Manual Mode (i.e. you will only need to enter the code one time per Manual
Mode session, regardless of the number of functions and channels you access). The supervisor Mfg
Code (see below) has precedence over the Bindicator Service Code (same as Mfg Code). If you enter the
Mfg Code in the Bindicator function under the Access Menu, the SonoTracker Series controller will not
require you to enter the Bindicator Service Code when you change values in the Service Menu.
5. Press the Esc Key to scroll up the menu tree or the Scan/Hold Key to return the display to vessel
monitoring. The Access Code is 'activated' when you leave the Manual Mode. Upon returning to the
Manual Mode and reentering the menu tree, you will be prompted to enter the code if you attempt to
change a system parameter. But, you will be prompted to enter the code only the first time you attempt
to change a system parameter within one Manual Mode session (i.e., you will only need to enter the
code one time per Manual Mode session, regardless of the number of parameters you change and
channels you access).
BINDICATOR
The SonoTracker Series has two factory code numbers. Certain troubleshooting functions require one of these
code numbers be entered before access to the function is permitted. The Service Code, described earlier in this
chapter, is entered when prompted by the display and is the same as Bindicator Mfg Code. The Mfg Code is
entered when in the Access Menu, as described below:
SON280020 Rev. C
BINDICATOR MFG CODE
The Bindicator Mfg Code is required to access hidden
menus, which are typically only used by Bindicator
Meters personnel for troubleshooting and testing the
equipment. The Bindicator Mfg Code number is:
9111
71
www.bindicator.com
on how

Advertisement

Table of Contents
loading

Table of Contents