Advertisement

KP
CONTROLLER
q
q
OK

Advertisement

Table of Contents
loading

Summary of Contents for FAAC KP CONTROLLER

  • Page 1 CONTROLLER...
  • Page 2: Ce Declaration Of Conformity

    Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Declares that: The KP CONTROLLER device complies with the essential safety requirements of the following EU Directive 2004/108/EC Electromagnetic Compatibility Directive And also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated or of which it will become a component has been identified and declared as conforming to the conditions of Directive 2006/42/EEC and subsequent amendments.
  • Page 3: Lithium Battery

    Leaf too heavy Motor failure 950 MPS board failure Set-up cycle requested Encoder failure Motor drive on 950 MPS board failure EEPROM failure Master and slave communication error KP controller and 950 I/0 board communication error 950N 732773 - Rev. B...
  • Page 4: Special Functions

    Reset restores normal operating conditions following some types of faults. b and c It is activated by simultaneously by pressing , until the KP controller goes off. KP CONTROLLER LOCK ( LOCK ) When activated, the Lock function inhibits operation of the KP-CONTROLLER.
  • Page 5 PROGRAMMING or q To enter programming mode, when the monitor is displaying the day-date-time, press either p Programming is divided into main menus (see Diagram 1) arranged by subject. or q Once the menu has been selected using p , press OK to access it. Each menu is divided into various level sub-menus for setting parameters.
  • Page 6 Diagram 2: Language selection Diagram 3: Setup 950N 732773 - Rev. B...
  • Page 7 Diagram 4: Lock Diagram 5: Diagnostics 950N 732773 - Rev. B...
  • Page 8 Diagram 6: Motion parameters 950N 732773 - Rev. B...
  • Page 9 Diagram 7: In/Out Setup 950N 732773 - Rev. B...
  • Page 10 Diagram 8: Other, Change password, Prog test 950N 732773 - Rev. B...
  • Page 11 Diagram 10: Timer Diagram 9: Clock 950N 732773 - Rev. B...
  • Page 12 Diagram 11: Programming timer 950N 732773 - Rev. B...
  • Page 13: Diagram Description

    DIAGRAM DESCRIPTION • 1.1 CLOSING SPEED • 1 LANGUAGE (Diagram 2) Sets the door speed during closing. Selects the language in which the messages are displayed. Standard value: level 8 • 2 SETUP (Diagram 3) - Adjustment: from 0 to 10 •...
  • Page 14 Master:Determines the master door (usually the inside one). Function Set the operative function to associate Slave: Determines the slave door. with the time band, using the following table as a reference: No Memory: Using interlock, it is necessary to wait for one door to close before commanding opening of the other: open MEANING FUNCTION...
  • Page 15 Operation is similar when coming from the opposite direction. SPECIAL APPLICATIONS 8.1.2 INTERLOCK WITHOUT INTERNAL SENSORS (buttons) APPLICATION WITH TWO INTERLOCKED LEAVES This application is recommended when the reduced The interlock function makes it possible to manage two distance between the two doors does not allow the use of doors (master and slave) so that opening of one depends two internal sensors;...
  • Page 16 8.2 APPLICATION WITH 2-LEAF DOOR (MASTER AND SLAVE ) The 2-LEAF function makes it possible to manage two opposing doors with synchronised movements and set (not modifiable) delay angles. The leaf controlled by the master automated system (see fig. 7 ) is the first to start opening and, when it has reached the opening angle set for the leaf delay, the slave will also begin its movement.
  • Page 18 POLAND Saint Priest, Lyon - France FAAC POLSKA SP.ZO.O tel. +33 4 72218700 Warszawa - Poland www.faac.fr tel. +48 22 8141422 FAAC FRANCE - AGENCE PARIS www.faac.pl Massy, Paris - France RUSSIA tel. +33 1 69191620 FAAC RUSSIA LLC www.faac.fr...

Table of Contents