Troubleshooting Guide - Oregon Scientific TS1X0 series User Manual

Outbreaker sports watch
Table of Contents

Advertisement

• Cleaning – Clean with a damp cloth. Do not use liquid
cleaning agents, benzene, thinner, or aerosols.
• Repair – Do not attempt to repair the product or modify the
circuitry by yourself. Contact the retailer or a qualified
repairman if the product requires servicing. Only use re-
placement parts that are recommended by the manufac-
turer.
• Do not scratch hard objects against the LCD display as this
may cause damage.

TROUBLESHOOTING GUIDE

This section includes a list of frequently asked questions for
problems you may encounter with the OUTBREAKER sports
watch. If your watch is not operating as you think it should,
check here before arranging for servicing.
Problem
Symptom
No power
Power will not turn
on.
Keys do not respond
Date / time
Date display is
is wrong
wrong
Check this
Remedy
Batteries are
Replace with new
exhausted.
batteries.
Batteries are inserted
Insert the batteries
incorrectly.
correctly ( 7).
Key lock in
Press SELECT/+ for 2
operation.
seconds (blinking icon will
(Key icon shown)
disappear).
Date not set
Set date correctly ( 9)
Cannot be changed when
TOUR Mode is operating.
Problem
Symptom
Time display is
wrong
Altitude
Reading is less than
reading is
0 (-20, etc.)
strange
Different height
reading at same
point after trip
No altitude
Alarm does not
alarm
sound
Temperature
Too high
reading is
strange
No alarm
Expected alarm
does not sound
Pressure
Too high or low
reading is
strange
Heart icon
Blank display
not working
26
Check this
Remedy
Time zone set
Reset time zone
incorrectly
Cannot be changed when
TOUR Mode is operating.
(TRIP shows on display)
Current altitude is
Adjust altitude, or accept
below ground (watch
reading
sea level setting)
Barometric changes
Minor pressure changes
may produce minimal
deviations in altitude
readings
Levels not set
Set levels ( 12)
Watch is too close to
Take off watch, wait 15
body
minutes, then try again
Levels not set
Set levels ( see relevant
MODE section)
Alarm not activated
Activate alarm ( see
relevant MODE section)
Is change due to
Reset after you have
wind, pressurized
changed locations
chamber, or
pressurized
environment
(airplane)?
Time out after 5
Press MODE to return to
minutes of inactivity
PULSE Mode
Chest belt is too far
Move chest belt closer or
from watch or poor
adjust contact with skin
skin contact

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts110Ts130Ts120

Table of Contents