3.1

System Requirements

3.1.1 Hardware Requirements

A system with a PCI Express x8 or x16 slot is required for installing the card.

3.1.2 Airflow Requirements

ConnectX-5 adapter cards are offered with two airflow patterns: from the heatsink to the network
ports and vice versa.
airflow numbers per OPN.
Table 11 - Airflow Color Legend
Rev 1.7
Unless otherwise specified, Mellanox products are designed to work in an environmentally
controlled data center with low levels of gaseous and dust (particulate) contamination.
The operation environment should meet severity level G1 as per ISA 71.04 for gaseous con-
tamination and ISO 14644-1 class 8 for cleanliness level.
For proper operation and performance, please make sure to use a PCIe x8 or x16 slot that can
supply sufficient power to your card. Refer to
for more power requirements.
Table 11
provides an airflow color legend. Please refer to
All cards in the system should be planned with the same airflow direction.
Direction
Mellanox Technologies
Section 7.9, "Airflow Specifications", on page 71
"Specifications"
Description
From the heatsink to the network
ports