Example:
OPENIBD_POST_START=/sbin/openibd_post_start.sh

4.1.3.6 Driver Load Upon System Boot

Upon system boot, the Mellanox drivers will be loaded automatically.
 To prevent automatic load of the Mellanox drivers upon system boot:
Add the following lines to the
Step 1.
Set
Step 2.
If the modules exist in the initramfs file, they can automatically be loaded by the kernel.
Step 3.
To prevent this behavior, update the initramfs using the operating systems' standard tools.
Note: The process of updating the initramfs will add the blacklists from step 1, and will pre-
vent the kernel from loading the modules automatically.

4.1.3.7 mlnxofedinstall Return Codes

The table below lists the
Table 14 - mlnxofedinstall Return Codes
Return Code
0
1
2
22
28
171
172
173
Rev 1.7
An example of OPENIBD_POST_START script for activating all interfaces is provided in
the MLNX_OFED package under the docs/scripts/openibd-post-start-configure-inter-
faces/ folder.
blacklist mlx4_core
blacklist mlx4_en
blacklist mlx5_core
blacklist mlx5_ib
in the
"ONBOOT=no"
"/etc/infiniband/openib.conf"
mlnxofedinstall
The Installation ended successfully
The installation failed
No firmware was found for the adapter device
Invalid parameter
Not enough free space
Not applicable to this system configuration. This can occur when the
required hardware is not present on the system.
Prerequisites are not met. For example, missing the required software
installed or the hardware is not configured correctly.
Failed to start the mst driver
Mellanox Technologies
"/etc/modprobe.d/mlnx.conf"
script return codes and their meanings.
Meaning
Driver Installation
file.
file.