Mellanox Technologies MCX453A-FCAT User Manual

Mellanox Technologies MCX453A-FCAT User Manual

Connectx-4 vpi single and dual port qsfp28 adapter card
Hide thumbs Also See for MCX453A-FCAT:
Table of Contents

Advertisement

ConnectX®-4 VPI Single and Dual Port
QSFP28 Adapter Card User Manual
P/N:
MCX453A-FCAT, MCX454A-FCAT, MCX455A-FCAT, MCX456A-FCAT,
MCX455A-ECAT, MCX456A-ECAT
Rev 2.0
www.mellanox.com
Mellanox Technologies

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MCX453A-FCAT and is the answer not in the manual?

Questions and answers

Summary of Contents for Mellanox Technologies MCX453A-FCAT

  • Page 1 ConnectX®-4 VPI Single and Dual Port QSFP28 Adapter Card User Manual P/N: MCX453A-FCAT, MCX454A-FCAT, MCX455A-FCAT, MCX456A-FCAT, MCX455A-ECAT, MCX456A-ECAT Rev 2.0 www.mellanox.com Mellanox Technologies...
  • Page 2 ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCT (S) AND/OR THE SYSTEM USING IT . THEREFORE , MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY .
  • Page 3: Table Of Contents

    4.1 Linux Driver ..........24 Rev 2.4 Mellanox Technologies...
  • Page 4 4.2.9 Performance Tuning ......... . . 50 Rev 2.4 Mellanox Technologies...
  • Page 5 Chapter 7 Specifications ......... . 55 7.1 MCX453A-FCAT Specifications........55 7.2 MCX454A-FCAT Specifications.
  • Page 6 MCX453A-FCAT Specifications Table ........55...
  • Page 7 Figure 12: MCX453A-FCAT Board Label (Example) ........
  • Page 8: Revision History

    February 2016 • Updated speed specifications in the following sections: • Product Overview on page 12. Features on page 14 • MCX453A-FCAT Specifications on page 56 • MCX454A-FCAT Specifications on page 57 • MCX455A-FCAT Specifications on page 58 • MCX456A-FCAT Specifications on page 59 •...
  • Page 9 Card on page 72. • Updated the following Board Labels: • MCX453A-FCAT Board Label (Example) on page 72. • MCX454A-FCAT Board Label (Example) on page 72. • MCX455A-FCAT Board Label (Example) on page 73. • MCX456A-FCAT Board Label (Example) on page 73.
  • Page 10: About This Manual

    About this Manual This User Manual describes Mellanox Technologies ConnectX®-4 Single and Dual QSFP28 port PCI Express x16 adapter cards. The User Manual provides details as to the interfaces of the adapter card, specifications, required software and firmware for operating the adapter card, and relevant documentation.
  • Page 11: Document Conventions

    The Mellanox support downloader contains software, firmware and knowledge database infor- mation for Mellanox products. Access the database from the Mellanox Support web page, http://www.mellanox.com => Support Or use the following link to go directly to the Mellanox Support Download Assistant page, http://www.mellanox.com/supportdownloader/. Rev 2.4 Mellanox Technologies...
  • Page 12: Chapter 1 Introduction

    Introduction Introduction This is the User Guide for Mellanox Technologies VPI adapter cards based on the ConnectX®-4 integrated circuit device. These adapters connectivity provide the highest performing and most flexible interconnect solution for PCI Express Gen3 servers used in Enterprise Data Centers, High-Performance Computing, and Embedded environments.
  • Page 13: Table 4: Single And Dual-Port Edr Adapter Cards

    Ethernet: 1/10/25/40/50/100 Gb/s Network Connector Types Single or Dual-port QSFP28 PCI Express (PCIe) SerDes Speed PCIe 3.0 x16 8GT/s RoHS Adapter IC Part Number MT27704A0-FDCF-EV MT27708A0-FDCF-EV Device ID 4115 for Physical Function (PF) 4116 for Virtual Function (VF) Rev 2.4 Mellanox Technologies...
  • Page 14: Features And Benefits

    TCP packet from the hardware offloading engines, placing higher loads on the host CPU. ConnectX-4 effectively addresses this by providing advanced NVGRE and VXLAN hardware offloading engines that encapsulate and decapsulate the overlay protocol. Rev 2.4 Mellanox Technologies...
  • Page 15: Operating Systems/Distributions

    • OpenFabrics Enterprise Distribution (OFED) • OpenFabrics Windows Distribution (WinOF-2) Connectivity • Interoperable with EDR InfiniBand or 1/10/25/40/50/100 Gb/s Ethernet switches • Passive copper cable with ESD protection • Powered connectors for optical and active cable support Rev 2.4 Mellanox Technologies...
  • Page 16: Chapter 2 Interfaces

    • Auto-negotiates to x16, x8, x4, x2, or x1 • Support for MSI/MSI-X mechanisms LED Interface There is a one bi-color I/O LED per port located on the adapter card. For LED specifications, please refer to Section 7.8, “Adapter Card LED Operations,” on page Rev 2.4 Mellanox Technologies...
  • Page 17: Chapter 3 Hardware Installation

    Section 3.5, “Card Installation Instructions,” on page 18. If you need to replace it with the short bracket that is included in the shipping box, please follow the instructions in this section. Rev 2.4 Mellanox Technologies...
  • Page 18: Removing The Existing Bracket

    Please note that the following figures are for illustration purposes only. 1. Before installing the card, make sure that the system is off and the power cord is not con- nected to the server. Please follow proper electrical grounding procedures. 2. Open the system case. Rev 2.4 Mellanox Technologies...
  • Page 19 (x16 in a x8). Align the adapter connector edge with the PCI Express connector slot. 4. Applying even pressure at both corners of the card, insert the adapter card into the PCI Express slot until firmly seated. Rev 2.4 Mellanox Technologies...
  • Page 20: Cables And Modules

    Insert the connector into the adapter card. Be careful to insert the connector straight into the cage. Do not apply any torque, up or down, to the connector cage in the adapter card. d. Make sure that the connector locks in place. Rev 2.4 Mellanox Technologies...
  • Page 21: Adapter Card Un-Installation Instructions

    3. Turn off the system and disconnect the power cord from the server. 3.7.2 Card Un-installation Please note that the following images are for illustration purposes only. 1. Verify that the system is powered off and unplugged. 2. Wait 30 seconds. Rev 2.4 Mellanox Technologies...
  • Page 22: Identify The Card In Your System

    3. Right click the mouse on your adapter's row and select properties to display the adapter card properties window. 4. Click the Details tab and select Hardware Ids (Windows 2012/R2) from the Properties pull- down menu. Rev 2.4 Mellanox Technologies...
  • Page 23: On Linux

    5. In the Value display box, check the fields VEN and DEV (fields are separated by ‘&’). In the display example above, notice the sub-string “PCI\VEN_15B3&DEV_1003”: VEN is equal to 0x15B3 – this is the Vendor ID of Mellanox Technologies; and DEV is equal to 1003 – this is a valid Mellanox Technologies PCI Device ID.
  • Page 24: Chapter 4 Driver Installation

    Step 1. The following example shows a system with an installed Mellanox HCA: # lspci -v | grep Mellanox 86:00.0 Network controller [0207]: Mellanox Technologies MT27620 Family Subsystem: Mellanox Technologies Device 0014 86:00.1 Network controller [0207]: Mellanox Technologies MT27620 Family Subsystem: Mellanox Technologies Device 0014 Download the ISO image to your host.
  • Page 25: Installing Mellanox Ofed

    The regular installation can be performed and weak- updates mechanism will create symbolic links to the MLNX_OFED kernel modules. 1. The firmware will not be updated if you run the install script with the ‘--without-fw-update’ option. Rev 2.4 Mellanox Technologies...
  • Page 26: Installation Procedure

    At this point, Mellanox OFED for Linux has already installed the OpenSM Subnet Manager on your machine. 4.1.3.1 Installation Procedure Login to the installation machine as root. Step 1. Mount the ISO image on your machine. Step 2. host1# mount -o ro,loop MLNX_OFED_LINUX-<ver>-<OS label>-<CPU arch>.iso /mnt Rev 2.4 Mellanox Technologies...
  • Page 27 Device #1: ---------- Device Type: ConnectX-4 Part Number: MCX453A-FCAT Description: ConnectX®-4 VPI adapter card, FDR IB 40/56 GbE, single- port QSFP28, PCIe3.0 x8, tall bracket, ROHS R6 PSID: MT_2190110032 PCI Device Name: 0b:00.0...
  • Page 28: Installation Results

    The path to the directory containing the log files will be displayed after running the installation script in the following format: "Logs dir: /tmp/MLNX_OFED_LINUX-<version>.<PID>.logs" Example: Logs dir: /tmp/MLNX_OFED_LINUX-x.x-x.logs 4.1.3.4 openibd Script As of MLNX_OFED v2.2-1.0.0 the script supports pre/post start/stop scripts: openibd Rev 2.4 Mellanox Technologies...
  • Page 29: Driver Load Upon System Boot

    4.1.4 Uninstalling Mellanox OFED Use the script to uninstall the Mellanox OFED package. /usr/sbin/ofed_uninstall.sh The script is part of the RPM. ofed-scripts 4.1.5 Installing MLNX_OFED using YUM This type of installation is applicable to RedHat/OEL, Fedora, XenServer Operating Systems. Rev 2.4 Mellanox Technologies...
  • Page 30: Setting Up Mlnx_Ofed Yum Repository

    # sudo rpm --import RPM-GPG-KEY-Mellanox warning: rpmts_HdrFromFdno: Header V3 DSA/SHA1 Signature, key ID 6224c050: NOKEY Retrieving key from file:///repos/MLNX_OFED/<MLNX_OFED file>/RPM-GPG-KEY-Mellanox Importing GPG key 0x6224C050: Userid: "Mellanox Technologies (Mellanox Technologies - Signing Key v2) <support@mel- lanox.com>" From : /repos/MLNX_OFED/<MLNX_OFED file>/RPM-GPG-KEY-Mellanox Is this ok [y/N]: Check that the key was successfully imported.
  • Page 31: Installing Mlnx_Ofed Using The Yum Tool

    : MLNX_OFED basic installer package for kernel 3.17.4-301.fc21.x86_64 (without KMP support) mlnx-ofed-guest-3.17.4-301.fc21.x86_64.noarch : MLNX_OFED guest installer package for kernel 3.17.4-301.fc21.x86_64 (without KMP support) mlnx-ofed-hpc-3.17.4-301.fc21.x86_64.noarch : MLNX_OFED hpc installer package for kernel 3.17.4-301.fc21.x86_64 (without KMP support) Rev 2.4 Mellanox Technologies...
  • Page 32: Uninstalling Mellanox Ofed Using The Yum Tool

    To update the firmware to the version included in MLNX_OFED package, you can either: • Run # yum install mlnx-fw-updater • Update the firmware to the latest version available on Mellanox Technologies’ Web site as described in Section 4.1.7, “Updating Firmware After Installation,” on page 4.1.5.3 Uninstalling Mellanox OFED using the YUM Tool...
  • Page 33: Installing Mlnx_Ofed Using Apt-Get

    Step 3. "/etc/apt/sources.list.d/mlnx- with the following content: _ofed.list" deb file:/<path to extracted MLNX_OFED package> ./ Download and install Mellanox Technologies GPG-KEY. Step 4. # wget -qO - http://www.mellanox.com/downloads/ofed/RPM-GPG-KEY-Mellanox | sudo apt-key add - Check that the key was successfully imported.
  • Page 34: Uninstalling Mellanox Ofed Using The Apt-Get Tool

    To update the device online on the machine from Mellanox site, use the following command line: mlxfwmanager --online -u -d <device> Example: mlxfwmanager --online -u -d 0000:09:00.0 Querying Mellanox devices firmware ... Device #1: ---------- Device Type: ConnectX-4 Part Number: MCX453A-FCAT Description: PSID: MT_1020120019 PCI Device Name: 0000:09:00.0 Port1 GUID: 0002c9000100d051 Port2 MAC: 0002c9000002 Versions:...
  • Page 35: Updating The Device Manually

    OEM card and now you wish to (manually) update firmware on your adapter card(s), you need to perform the steps below. The following steps are also appropriate in case you wish to burn newer firmware that you have downloaded from Mellanox Technologies’ Web site (http:// www.mellanox.com...
  • Page 36: Enrolling Mellanox's X.509 Public Key On Your Systems

    "\.ko$" | xargs strip -g After the signature has been removed, a message as the below will no longer be presented upon module loading: "Request for unknown module key 'Mellanox Technologies signing key: 61feb074fc7292f958419386ffdd9d5ca999e403' err -11" Rev 2.4 Mellanox Technologies...
  • Page 37: Performance Tuning

    Obtain the machine architecture. Step 1. For Windows Server 2012 / 2012 R2 / 8.1 Client To go to the Start menu, position your mouse in the bottom-right corner of the Remote Desktop of your screen. Rev 2.4 Mellanox Technologies...
  • Page 38: Installing Mellanox Winof-2 Driver

    [Optional] Manually configure your setup to contain the logs option. Step 2. > MLNX_WinOF2-1_35_All_x64.exe /v"/l*vx [LogFile]" [Optional] If you do not want to upgrade your firmware version Step 3. > MLNX_WinOF2-1_35_All_x64.exe /v" MT_SKIPFWUPGRD=1" 1. MT_SKIPFWUPGRD default value is False Rev 2.4 Mellanox Technologies...
  • Page 39 Driver Installation Click Next in the Welcome screen. Step 4. Read then accept the license agreement and click Next. Step 5. Rev 2.4 Mellanox Technologies...
  • Page 40 Driver Installation Select the target folder for the installation. Step 6. Rev 2.4 Mellanox Technologies...
  • Page 41 If the user has a standard Mellanox card with an older firmware version, the firmware will be updated accordingly. However, if the user has both an OEM card and a Mellanox card, only the Mellanox card will be updated. Rev 2.4 Mellanox Technologies...
  • Page 42 Analyze tools - install the tools that can be used either to diagnose or analyze the InfiniBand envi- ronment. • SDK - contains the libraries and DLLs for developing InfiniBand application over IBAL. • Documentation - contains the User Manual and Release Notes Rev 2.4 Mellanox Technologies...
  • Page 43 Driver Installation • Management tools - installation tools used for management, such as mlxstat. b. Click Install to start the installation. Rev 2.4 Mellanox Technologies...
  • Page 44 Driver Installation In case firmware upgrade option was checked in Step 7., you will be notified if a firmware Step 9. upgrade is required. Click Finish to complete the installation. Step 10. Rev 2.4 Mellanox Technologies...
  • Page 45: Unattended Installation

    Upon installation completion, the inf files can be located at: • %ProgramFiles%\Mellanox\MLNX_WinOF2\Drivers\<OS> To see the Mellanox network adapters, display the Device Manager and pull down the “Net- work adapters” menu. 1. MT_NDPROPERTY default value is True 2. MT_SKIPFWUPGRD default value is False Rev 2.4 Mellanox Technologies...
  • Page 46: Extracting Files Without Running Installation

    Open a CMD console-> Click Start-> Task Manager-> File-> Run new task-> and enter Step 1. CMD. Extract the driver and the tools: Step 2. > MLNX_WinOF2-1_35_All_x64 /a • To extract only the driver files. > MLNX_WinOF2-1_35_All_x64 /a /vMT_DRIVERS_ONLY=1 Rev 2.4 Mellanox Technologies...
  • Page 47 Driver Installation Click Next to create a server image. Step 3. Click Change and specify the location in which the files are extracted to. Step 4. Rev 2.4 Mellanox Technologies...
  • Page 48: Uninstalling Mellanox Winof-2 Driver

    To complete the extraction, click Finish. Step 6. 4.2.6 Uninstalling Mellanox WinOF-2 Driver 4.2.6.1 Attended Uninstallation  To uninstall MLNX_WinOF2 on a single node: Click Start -> Control Panel -> Programs and Features -> MLNX_WinOF2 -> Uninstall. Rev 2.4 Mellanox Technologies...
  • Page 49: Unattended Uninstallation

    Extract the driver to a local directory (see Section 4.2.5, “Extracting Files Without Running Step 3. Installation,” on page 46). Copy the contents of this directory to C:\WS2016TP5_Drivers. The directory contents should appear as follows: Rev 2.4 Mellanox Technologies...
  • Page 50: Online Update

    To upgrade, it is recommended to run a script that will execute all the required upgrade commands. 4.2.9 Performance Tuning For further information on WinOF-2 performance, please refer to the Performance Tuning Guide for Mellanox Network Adapters. Rev 2.4 Mellanox Technologies...
  • Page 51: Chapter 5 Updating Adapter Card Firmware

    => Products => Software => Firmware Tools. Firmware Update Example [server1]# ./mlxup Querying Mellanox devices firmware ... Device Type: ConnectX4 Part Number: MCX453A-FCAT Description: PSID: MT_2190110032 PCI Device Name: 0000:06:00.0 Base GUID: e41d2d0300fd8b8a Versions: Current Available 12.12.1100...
  • Page 52: Chapter 6 Troubleshooting

    • Verify that your switch and adapter port are compatible • Check that the latest driver is loaded Link light is on, but with no • Check that both the adapter and its link are set to the same communication speed and duplex settings established Rev 2.4 Mellanox Technologies...
  • Page 53: Linux

    Tool (MFT) Once installed, run: mst start mst status flint –d <mst_device> q ibstat Ports Information lbv_devinfo To download the latest firmware version refer to Firmware Version http://www.mellanox.com/supportdownloader Upgrade cat /var/log/messages Collect Log File dmesg > system.log Rev 2.4 Mellanox Technologies...
  • Page 54: Windows

    –d <mst_device> –i <firmware_bin_file> b • Event log viewer • MST device logs: • mst start • mst status Collect log file • C:\Users\Administrator> flint –d <mst_device> dc > dump_con- figuration.log • C:\Users\Administrator> mstdump <mst_device> dc > mst- dump.log Rev 2.4 Mellanox Technologies...
  • Page 55: Chapter 7 Specifications

    Specifications Specifications MCX453A-FCAT Specifications Table 8 - MCX453A-FCAT Specifications Table Size: 2.71 in. x5.6 in. (68.90mm x 142.24 mm) – low profile Physical Connector: Single QSFP28 InfiniBand (Copper and optical) InfiniBand: IBTA v1.3 Auto-Negotiation : 1X/2X/4X SDR (2.5Gb/s per lane), DDR (5Gb/s per lane), QDR (10Gb/s per lane), FDR10 (10.3125Gb/s per lane), FDR (14.0625Gb/s per lane) port...
  • Page 56: Mcx454A-Fcat Specifications

    The ConnectX-4 adapters supplement the IBTA auto-negotiation specification to get better bit error rates and longer cable reaches. This supplemental feature only initiates when connected to another Mellanox InfiniBand product. b. Typical power for ATIS traffic load. c. For both operational and non-operational states. Rev 2.4 Mellanox Technologies...
  • Page 57: Mcx455A-Fcat Specifications

    The ConnectX-4 adapters supplement the IBTA auto-negotiation specification to get better bit error rates and longer cable reaches. This supplemental feature only initiates when connected to another Mellanox InfiniBand product. b. Typical power for ATIS traffic load. c. For both operational and non-operational states. Rev 2.4 Mellanox Technologies...
  • Page 58: Mcx456A-Fcat Specifications

    The ConnectX-4 adapters supplement the IBTA auto-negotiation specification to get better bit error rates and longer cable reaches. This supplemental feature only initiates when connected to another Mellanox InfiniBand product. b. Typical power for ATIS traffic load. c. For both operational and non-operational states. Rev 2.4 Mellanox Technologies...
  • Page 59: Mcx455A-Ecat Specifications

    The ConnectX-4 adapters supplement the IBTA auto-negotiation specification to get better bit error rates and longer cable reaches. This supplemental feature only initiates when connected to another Mellanox InfiniBand product. b. Typical power for ATIS traffic load. c. For both operational and non-operational states. Rev 2.4 Mellanox Technologies...
  • Page 60: Mcx456A-Ecat Specifications

    The ConnectX-4 adapters supplement the IBTA auto-negotiation specification to get better bit error rates and longer cable reaches. This supplemental feature only initiates when connected to another Mellanox InfiniBand product. b. Typical power for ATIS traffic load. c. For both operational and non-operational states. Rev 2.4 Mellanox Technologies...
  • Page 61: Airflow Specifications

    Air Flow (LFM) Air Flow Direction Heat Sink to Port Port to Heat Sink Active Active Active Active Cable Type Passive Passive 1.5W 3.5W 1.5W 3.5W MCX453A-FCAT – – MCX454A-FCAT – – MCX455A-FCAT – – MCX456A-FCAT – – MCX455A-ECAT – –...
  • Page 62: Board Mechanical Drawing And Dimensions

    All dimensions are in millimeters. All the mechanical tolerances are +/- 0.1mm. Figure 3: Mechanical Drawing of the Single-port x8 Adapter Cards 142.24 68.90 Figure 4: Mechanical Drawing of the Dual-port x8 Adapter Cards 142.24 68.90 Rev 2.4 Mellanox Technologies...
  • Page 63: Figure 5: Mechanical Drawing Of The Single-Port X16 Adapter Card

    Specifications Figure 5: Mechanical Drawing of the Single-port x16 Adapter Card 142.24 68.90 Figure 6: Mechanical Drawing of the Dual-port x16 Adapter Card 142.24 68.90 Rev 2.4 Mellanox Technologies...
  • Page 64: Bracket Mechanical Drawings

    Specifications 7.10 Bracket Mechanical Drawings Figure 7: Single-port Bracket Rev 2.4 Mellanox Technologies...
  • Page 65: Figure 8: Dual-Port Bracket

    Specifications Figure 8: Dual-port Bracket Rev 2.4 Mellanox Technologies...
  • Page 66: Appendix A Interface Connectors Pinout

    Table 15 - Connector Pin Number and Name to Signal Name Map Connector Pin Number Connector Pin Name Port A Signal Name TXN_2 Tx2n TXP_2 Tx2p TXN_4 Tx4n TXP_4 Tx4p ModSelL_Port0 ModSelL ResetL_Port0 ResetL VccRx RXP_3 Rx3p RXN_3 Rx3n RXP_1 Rx1p Rev 2.4 Mellanox Technologies...
  • Page 67 Connector Pin Number Connector Pin Name Port A Signal Name RXN_1 Rx1n RXN_2 Rx2n RXP_2 Rx2p RXN_4 Rx4n RXP_4 Rx4p ModPrsl_Port0 Mod PrsL IntL IntL VccTx Vcc1 LPMode_Port0 LPMode TXP_3 Tx3p TXN_3 Tx3n TXP_1 Tx1p TXN_1 Tx1n Rev 2.4 Mellanox Technologies...
  • Page 68: Pci Express X8 Or X16 Edge Connector Pinout

    Edge Connector Pinout The adapter cards support PCI Express 3.0 x8 or x16 edge connector and the PCI Expressx8 or x816 standard pinout according to the PCI Express 3.0 specification. Figure 10: PCIe x8 Connector Pinout Rev 2.4 Mellanox Technologies...
  • Page 69: Figure 11: Pcie X16 Connector Pinout

    Figure 11: PCIe x16 Connector Pinout Rev 2.4 Mellanox Technologies...
  • Page 70: Appendix B Finding The Guid/Mac And Serial Number On The Adapter Card

    GUID and a MAC (derived from the GUID). The revisions indicated on the labels in the following figure do not necessarily repre- sent the latest revisions of the card. Figure 12: MCX453A-FCAT Board Label (Example) Figure 13: MCX454A-FCAT Board Label (Example) Rev 2.4...
  • Page 71: Figure 14: Mcx455A-Fcat Board Label (Example)

    Figure 14: MCX455A-FCAT Board Label (Example) Figure 15: MCX456A-FCAT Board Label (Example) Figure 16: MCX455A-ECAT Board Label (Example) Rev 2.4 Mellanox Technologies...
  • Page 72: Figure 17: Mcx456A-Ecat Board Label (Example)

    Figure 17: MCX456A-ECAT Board Label (Example) Rev 2.4 Mellanox Technologies...
  • Page 73: Appendix C Safety Warnings

    6. Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regula- tions. 7. Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical codes. Rev 2.4 Mellanox Technologies...
  • Page 74 Caution – Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure. CLASS 1 LASER PRODUCT and reference to the most recent laser standards: IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+ A2:20. Rev 2.4 Mellanox Technologies...
  • Page 75: Appendix D Avertissements De Sécurité D'installation (Warnings In French)

    L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur. 7. Codes électriques locaux et nationaux Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux. Rev 1.9 Mellanox Technologies...
  • Page 76 Mise en garde – l'utilisation de commandes ou de réglages ou l'exécution de procédures autres que ce qui est spécifié dans les présentes peut engendrer une exposition au rayonnement grave. PRODUIT LASER DE CLASSE 1 » et références aux normes laser les plus récentes CEI 60 825-1 Rev 1.9 Mellanox Technologies...
  • Page 77: Appendix E Advertencias De Seguridad Para La Instalación (Warnings In Spanish)

    La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales. 7. Códigos eléctricos locales y nacionales Este equipo se debe instalar conforme a los códigos eléctricos locales y nacionales. Rev 2.4 Mellanox Technologies...
  • Page 78 Precaución: el uso de controles o ajustes o la realización de procedimientos distintos de los que aquí se especifican podrían causar exposición a niveles de radiación peligrosos. PRODUCTO LÁSER DE CLASE 1 y referencia a las normas de láser más recientes: IEC 60825-1 Rev 2.4 Mellanox Technologies...
  • Page 79: Appendix F Avertissements De Sécurité D'installation (Warnings In French)

    L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur. 7. Codes électriques locaux et nationaux Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux. Rev 2.4 Mellanox Technologies...
  • Page 80 Mise en garde – l'utilisation de commandes ou de réglages ou l'exécution de procédures autres que ce qui est spécifié dans les présentes peut engendrer une exposition au rayonnement grave. PRODUIT LASER DE CLASSE 1 » et références aux normes laser les plus récentes CEI 60 825-1 Rev 2.4 Mellanox Technologies...

Table of Contents