Mellanox Technologies ConnectX-5 Ex User Manual

Mellanox Technologies ConnectX-5 Ex User Manual

Ethernet sfp28 and qsfp28 ports adapter cards
Hide thumbs Also See for ConnectX-5 Ex:
Table of Contents

Advertisement

Mellanox ConnectX®-5 and ConnectX®-5 Ex Ethernet
SFP28 and QSFP28 Ports Adapter Cards User Manual
P/N:
MCX512A-ACAT, MCX511F-ACAT, MCX512F-ACAT,MCX516A-BDAT, MCX515A-GCAT,
MCX516A-GCAT, MCX515A-CCAT, MCX516A-CCAT, MCX516A-CDAT
Rev 1.7
www.mellanox.com
Mellanox Technologies

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ConnectX-5 Ex and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mellanox Technologies ConnectX-5 Ex

  • Page 1 Mellanox ConnectX®-5 and ConnectX®-5 Ex Ethernet SFP28 and QSFP28 Ports Adapter Cards User Manual P/N: MCX512A-ACAT, MCX511F-ACAT, MCX512F-ACAT,MCX516A-BDAT, MCX515A-GCAT, MCX516A-GCAT, MCX515A-CCAT, MCX516A-CCAT, MCX516A-CDAT Rev 1.7 www.mellanox.com Mellanox Technologies...
  • Page 2 ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCT (S) AND/OR THE SYSTEM USING IT . THEREFORE , MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY .
  • Page 3: Table Of Contents

    3.8.1 On Windows ..........25 Rev 1.7 Mellanox Technologies...
  • Page 4 4.2.7 Firmware Upgrade ..........54 Rev 1.7 Mellanox Technologies...
  • Page 5 Sicherheitshinweise (Warnings in German) ..... 83 Advertencias de seguridad para la instalación (Warnings in Spanish) 85 Rev 1.7 Mellanox Technologies...
  • Page 6 Table 4: ConnectX-5 Ex Ethernet Adapter Cards ....... . . 12 Table 5: ConnectX-5 Ethernet Adapter Cards .
  • Page 7 Figure 16: MCX516A-CDAT Board Label (Example) ........78 Rev 1.7 Mellanox Technologies...
  • Page 8: Revision History

    • MCX516A-CCAT Specifications on page 70 • MCX516A-CDAT Specifications on page 64 • Updated Airflow Specifications on page 71 April 2017 • Updated Product Overview on page 12 • Updated Installation Instructions on page 21 March 2017 First release Rev 1.7 Mellanox Technologies...
  • Page 9: About This Manual

    About This Manual This User Manual describes Mellanox Technologies ConnectX®-5 and ConnectX®-5 Ex Ether- net Single and Dual SFP28 and QSFP28 port PCI Express x8/x16 adapter cards. It provides details as to the interfaces of the board, specifications, required software and firmware for operat- ing the board, and relevant documentation.
  • Page 10 • Tel: +1.408.916.0055 Customers who purchased Mellanox M-1 Global Support Services, please see your contract for details regarding Technical Support. Customers who purchased Mellanox products through a Mellanox approved reseller should first seek assistance through their reseller. Rev 1.7 Mellanox Technologies...
  • Page 11: Chapter 1 Introduction

    Introduction Introduction This is the User Guide for Mellanox Technologies Ethernet adapter cards based on the Con- nectX®-5 integrated circuit device. These adapters connectivity provide the highest performing low latency and most flexible interconnect solution for PCI Express Gen 3.0/4.0 servers used in Enterprise Data Centers and High-Performance Computing environments.
  • Page 12: Product Overview

    The following section provides the ordering part number, port speed, number of ports, and PCI Express speed. Each adapter comes with two bracket heights - short and tall. Table 4 - ConnectX-5 Ex Ethernet Adapter Cards Model ConnectX-5 Ex Ethernet Adapter Cards...
  • Page 13: Features And Benefits

    Adapter functionality enabling reduced CPU overhead allowing more available CPU for computation tasks. 2(TM) CPU Offload Open VSwitch (OVS) offload using ASAP • Flexible match-action flow tables • Tunneling encapsulation / decapsulation Rev 1.7 Mellanox Technologies...
  • Page 14: Operating Systems/Distributions

    • VMware • OpenFabrics Enterprise Distribution (OFED) • OpenFabrics Windows Distribution (WinOF-2) Connectivity • Interoperable with 1/10/25/40/50/100 Gb/s Ethernet switches • Passive copper cable with ESD protection • Powered connectors for optical and active cable support Rev 1.7 Mellanox Technologies...
  • Page 15: Chapter 2 Interfaces

    7. Ethernet traffic is transmitted through the cards' SFP28 and QSFP28 connectors. PCI Express Interface Table 8 describes the supported PCIe interface in ConnectX-5 and ConnectX-5 Ex adapter cards. Table 8 - PCI Express Interface ConnectX-5 Supported PCIe Interface Features PCIe Gen 3.0 (1.1 and 2.0 compatible)
  • Page 16: Led Interface

    Voltage Regulators The voltage regulator power is derived from the PCI Express edge connector 12V supply pins. These voltage supply pins feed on-board regulators that provide the necessary power to the vari- ous components on the card. Rev 1.7 Mellanox Technologies...
  • Page 17: Chapter 3 Hardware Installation

    Install ConnectX-5 adapter card in the system Refer to “Installation Instructions” Connect cables or modules to the card Refer to “Cables and Modules” Identify ConnectX-5 adapter card in the system Refer to “Identify the Card in Your System” Rev 1.7 Mellanox Technologies...
  • Page 18: System Requirements

    Please refer to “Specifications” airflow numbers per OPN. All cards in the system should be planned with the same airflow direction. Table 11 - Airflow Color Legend Direction Description From the heatsink to the network ports Rev 1.7 Mellanox Technologies...
  • Page 19: Software Requirements

    Check the parts for visible damage that may have occurred during ship- ping. Please note that the cards must be placed on an antistatic surface. For package contents please refer to Section 1.2, “Package Content”, on page 12. Rev 1.7 Mellanox Technologies...
  • Page 20: Bracket Replacement Instructions

    Due to risk of damaging the EMI fingers, it is not recommended to replace the bracket more than three times. To replace the brackets you will need the following parts: Rev 1.7 Mellanox Technologies...
  • Page 21: Removing The Existing Bracket

    Please note that the following figures are for illustration purposes only. 1. Before installing the card, make sure that the system is off and the power cord is not con- nected to the server. Please follow proper electrical grounding procedures. 2. Open the system case. Rev 1.7 Mellanox Technologies...
  • Page 22 Hardware Installation 3. Place the adapter in an available PCI Express slot. 4. Applying even pressure at both corners of the card, insert the adapter card into the PCI Express slot until firmly seated. Rev 1.7 Mellanox Technologies...
  • Page 23: Cables And Modules

    Make sure that the connector locks in place. When installing cables make sure that the latches engage. Always install and remove cables by pushing or pulling the cable and connector in a straight line with the card. Rev 1.7 Mellanox Technologies...
  • Page 24: Adapter Card Uninstallation Instructions

    Please note that the following images are for illustration purposes only. 1. Verify that the system is powered off and unplugged. 2. Wait 30 seconds. 3. To remove the card, disengage the retention mechanisms on the bracket (clips or screws). Rev 1.7 Mellanox Technologies...
  • Page 25: Identify The Card In Your System

    1. Open Device Manager on the server. Click Start => Run, and then enter “devmgmt.msc”. 2. Expand System Devices and locate your Mellanox ConnectX-5 adapter card. 3. Right click the mouse on your adapter's row and select Properties to display the adapter card properties window. Rev 1.7 Mellanox Technologies...
  • Page 26: Figure 3: Pci Device (Example)

    “PCI\VEN_15B3&DEV_1003”: VEN is equal to 0x15B3 – this is the Vendor ID of Mellanox Technologies; and DEV is equal to 1018 (for ConnectX-5) or 1019 (for ConnectX-5 Ex) – this is a valid Mellanox Technologies PCI Device ID.
  • Page 27: On Linux

    Hardware Installation 3.8.2 On Linux Get the device location on the PCI bus by running lspci and locating lines with the string “Mellanox Technologies”: lspci |grep -i Mellanox Network controller: Mellanox Technologies MT28800 Family [ConnectX-5] Rev 1.7 Mellanox Technologies...
  • Page 28: Chapter 4 Driver Installation

    Step 1. The following example shows a system with an installed Mellanox adapter cards: # lspci -v | grep Mellanox 86:00.0 Network controller [0207]: Mellanox Technologies MT27620 Family Subsystem: Mellanox Technologies Device 0014 86:00.1 Network controller [0207]: Mellanox Technologies MT27620 Family Subsystem: Mellanox Technologies Device 0014 Download the ISO image to your host.
  • Page 29: Installing Mellanox Ofed

    NFS. To install on all the cluster nodes, use cluster-aware tools (such as pdsh). 1. The firmware will not be updated if you run the install script with the ‘--without-fw-update’ option. Rev 1.7 Mellanox Technologies...
  • Page 30 For your machine to be part of the InfiniBand/VPI fabric, a Subnet Manager must be running on one of the fabric nodes. At this point, Mellanox OFED for Linux has already installed the OpenSM Subnet Manager on your machine. For the list of installation options, run: ./mlnxofedinstall --h Rev 1.7 Mellanox Technologies...
  • Page 31: Installation Procedure

    ./mlnxofedinstall --without-dkms --add-kernel-support --kernel <kernel version in chroot> --without-fw-update --force For example: ./mlnxofedinstall --without-dkms --add-kernel-support --kernel 3.13.0-85-generic --without-fw-update --force Note that the path to kernel sources (--kernel-sources) should be added if the sources are not in their default location. Rev 1.7 Mellanox Technologies...
  • Page 32 • ConnectX-5/ConnectX-5 Ex - perform a standard reboot Otherwise, restart the driver by running: "/etc/init.d/openibd restart" After installation completion, information about the Mellanox OFED installation, such as prefix,...
  • Page 33: Installation Results

    "Logs dir: /tmp/MLNX_OFED_LINUX-<version>.<PSID>.logs" Example: Logs dir: /tmp/MLNX_OFED_LINUX-4.4-1.0.0.0.IBMM2150110033.logs 4.1.3.5 openibd Script As of MLNX_OFED v2.2-1.0.0 the script supports pre/post start/stop scripts: openibd This can be controlled by setting the variables below in the /etc/infiniband/openibd.conf file. OPENIBD_PRE_START OPENIBD_POST_START OPENIBD_PRE_STOP OPENIBD_POST_STOP Rev 1.7 Mellanox Technologies...
  • Page 34: Driver Load Upon System Boot

    Not applicable to this system configuration. This can occur when the required hardware is not present on the system. Prerequisites are not met. For example, missing the required software installed or the hardware is not configured correctly. Failed to start the mst driver Rev 1.7 Mellanox Technologies...
  • Page 35: Uninstalling Mellanox Ofed

    # sudo rpm --import RPM-GPG-KEY-Mellanox warning: rpmts_HdrFromFdno: Header V3 DSA/SHA1 Signature, key ID 6224c050: NOKEY Retrieving key from file:///repos/MLNX_OFED/<MLNX_OFED file>/RPM-GPG-KEY-Mellanox Importing GPG key 0x6224C050: Userid: "Mellanox Technologies (Mellanox Technologies - Signing Key v2) <support@mel- lanox.com>" From : /repos/MLNX_OFED/<MLNX_OFED file>/RPM-GPG-KEY-Mellanox Is this ok [y/N]: Check that the key was successfully imported.
  • Page 36: Installing Mlnx_Ofed Using The Yum Tool

    RHEL and SLES. For other operating systems, kernel module RPM packages are provided only for the operating systems' default kernel. In this case, the group RPM packages have the supported kernel version in their package's name. Rev 1.7 Mellanox Technologies...
  • Page 37: Uninstalling Mellanox Ofed Using The Yum Tool

    0:0.4.9-9 rds-devel.x86_64 0:2.0.7-1.12 rds-tools.x86_64 0:2.0.7-1.12 sdpnetstat.x86_64 0:1.60-26 srptools.x86_64 0:1.0.2-12 Complete! 4.1.5.3 Uninstalling Mellanox OFED Using the YUM Tool Use the script to uninstall the Mellanox OFED package. The /usr/sbin/ofed_uninstall.sh script is part of the ofed-scripts RPM. Rev 1.7 Mellanox Technologies...
  • Page 38: Installing Mlnx_Ofed Using Apt-Get Tool

    Step 3. with the following content: "/etc/apt/sources.list.d/mlnx_ofed.list" # deb file:/<path to extracted MLNX_OFED package>/DEBS ./ Download and install Mellanox Technologies GPG-KEY. Step 4. # wget -qO - http://www.mellanox.com/downloads/ofed/RPM-GPG-KEY-Mellanox | sudo apt-key add - Check that the key was successfully imported.
  • Page 39: Uninstalling Mellanox Ofed Using The Apt-Get Tool

    To update the firmware to the version included in MLNX_OFED package, run: # apt-get install mlnx-fw-updater Update the firmware to the latest version available on Mellanox Technologies’ Web site as described in Section 5, “Updating Adapter Card Firmware”, on page 58.
  • Page 40: Updating The Device Manually

    OEM card and now you wish to (manually) update firmware on your adapter card(s), you need to perform the steps below. The following steps are also appropriate in case that you wish to burn newer firmware that you have downloaded from Mellanox Technologies’ Web site (http://www.mellanox.com > Support > Firmware Download).
  • Page 41: Enrolling Mellanox's X.509 Public Key On Your Systems

    | xargs rpm -ql | grep "\.ko$" | xargs strip -g After the signature has been removed, a massage as the below will no longer be presented upon module loading: "Request for unknown module key 'Mellanox Technologies signing key: 61feb074fc7292f958419386ffdd9d5ca999e403' err -11" Rev 1.7...
  • Page 42: Performance Tuning

    Depending on the application of the user's system, it may be necessary to modify the default con- figuration of network adapters based on the ConnectX® adapters. In case that tuning is required, please refer to the Performance Tuning Guide for Mellanox Network Adapters. Rev 1.7 Mellanox Technologies...
  • Page 43: Windows Driver

    Step 2. http://www.mellanox.com => Products =>Ethernet Drivers => Windows SW/Drivers. Download the .exe image according to the architecture of your machine (see Step 1). The Step 3. name of the .exe is in the following format MLNX_WinOF2-<version>_x<arch>.exe. Rev 1.7 Mellanox Technologies...
  • Page 44: Installing Mellanox Winof-2 Driver

    [Optional] Manually configure your setup to contain the logs option (replace “LogFile” with Step 2. the relevant directory): MLNX_WinOF2-1_10_<revision_version>_All_x64.exe /v"/l*vx [LogFile]" [Optional] If you do not want to upgrade your firmware version Step 3. MLNX_WinOF2-1_10_<revision_version>_All_x64.exe /v" MT_SKIPFWUPGRD=1" 1. MT_SKIPFWUPGRD default value is False Rev 1.7 Mellanox Technologies...
  • Page 45 Driver Installation Click Next in the Welcome screen. Step 4. Read then accept the license agreement and click Next. Step 5. Rev 1.7 Mellanox Technologies...
  • Page 46 Driver Installation Select the target folder for the installation. Step 6. Rev 1.7 Mellanox Technologies...
  • Page 47 • Performance tools - install the performance tools that are used to measure performance in user environment • Documentation - contains the User Manual and Release Notes • Management tools - installation tools used for management, such as mlxstat Rev 1.7 Mellanox Technologies...
  • Page 48 Driver Installation • Diagnostic Tools - installation tools used for diagnostics, such as mlx5cmd b. Click Next to install the desired tools. Click Install to start the installation. Step 9. Rev 1.7 Mellanox Technologies...
  • Page 49 Driver Installation In case that firmware upgrade option was checked in Step 7, you will be notified if a firm- Step 10. ware upgrade is required. Click Finish to complete the installation. Step 11. Rev 1.7 Mellanox Technologies...
  • Page 50: Unattended Installation

    Upon installation completion, the inf files can be located at: • %ProgramFiles%\Mellanox\MLNX_WinOF2\Drivers\<OS> To see the Mellanox network adapters, display the Device Manager and pull down the “Network adapters” menu. 1. MT_NDPROPERTY default value is True 2. MT_SKIPFWUPGRD default value is False Rev 1.7 Mellanox Technologies...
  • Page 51: Extracting Files Without Running Installation

    Open a CMD console-> Click Start-> Task Manager-> File-> Run new task-> and enter Step 1. CMD. Extract the driver and the tools: Step 2. MLNX_WinOF2-1_10_All_x64 /a To extract only the driver files. MLNX_WinOF2-1_10_All_x64 /a /vMT_DRIVERS_ONLY=1 Rev 1.7 Mellanox Technologies...
  • Page 52 Driver Installation Click Next to create a server image. Step 3. Click Change and specify the location in which the files are extracted to. Step 4. Rev 1.7 Mellanox Technologies...
  • Page 53 Driver Installation Click Install to extract this folder, or click Change to install to a different folder. Step 5. To complete the extraction, click Finish. Step 6. Rev 1.7 Mellanox Technologies...
  • Page 54: Uninstalling Mellanox Winof-2 Driver

    Download the driver (MLNX_WinOF2_MLNX_WinOF2-1_64_mlx5_All_win2016_x64_- Step 2. fre_1_64_15407.exe). Extract the driver to a local directory (see Section 4.2.5, “Extracting Files Without Running Step 3. Installation”, on page 51). Copy the contents of this directory to C:\WS2016TP5_Drivers. Step 4. Rev 1.7 Mellanox Technologies...
  • Page 55: Online Update

    When upgrading the driver on a server where the remote connection was done over Mella- nox device, there will be a loss of connectivity. To upgrade, it is recommended to run a script that will execute all the required upgrade commands. Rev 1.7 Mellanox Technologies...
  • Page 56: Vmware Driver

    3. Reboot the machine. 4. Verify the driver was installed successfully. esxcli software vib list | grep nmlx nmlx5-core 4.16.8.8-1OEM.650.0.0.4240417 PartnerSupported 2017-01-31 nmlx5-rdma 4.16.8.8-1OEM.650.0.0.4240417 PartnerSupported 2017-01-31 After the installation process, all kernel modules are loaded automatically upon boot. Rev 1.7 Mellanox Technologies...
  • Page 57: Removing Earlier Mellanox Driver

    • ESXi 6.5 File: mft-4.6.0.48-10EM-650.0.0.4598673.x86_64.vib MD5SUM: 0804cffe30913a7b4017445a0f0adbe1 2. Install the image according to the steps described in the MFT User Manual. The following procedure requires custom boot image downloading, mounting and boot- ing from a USB device. Rev 1.7 Mellanox Technologies...
  • Page 58: Chapter 5 Updating Adapter Card Firmware

    0000e41d2da206d4 Versions: Current Available 16.24.1000 16.24.1000 Status: Up to date Perform FW update? [y/N]: y Device #1: Up to date Device #2: Updating FW ... Done Restart needed for updates to take effect. Log File: /var/log/mlxup/mlxup-yyyymmdd.log Rev 1.7 Mellanox Technologies...
  • Page 59: Chapter 6 Troubleshooting

    Verify that your switch and adapter port are compatible • Check that the latest driver is loaded Link light is on, but with no • Check that both the adapter and its link are set to the same speed and communication established duplex settings Rev 1.7 Mellanox Technologies...
  • Page 60: Linux

    -d <mst_device> q ibstat Ports Information ibv_devinfo To download the latest firmware version refer to Firmware Version Upgrade http://www.mellanox.com/supportdownloader cat /var/log/messages dmesg >> system.log Collect Log File journalctl (Applicable on new operating systems) cat /var/log/syslog Rev 1.7 Mellanox Technologies...
  • Page 61: Windows

    –d <mst_device> –i <firmware_bin_file> b • Event log viewer • MST device logs: • mst start Collect Log File • mst status • flint –d <mst_device> dc > dump_configuration.log • mstdump <mst_device> dc > mstdump.log Rev 1.7 Mellanox Technologies...
  • Page 62: Chapter 7 Specifications

    Specifications Specifications Table 20 - Direct links for Specifications Table per OPN Marketing Description MCX516A-BDAT MCX516A-BDAT Specifications on page 63 ConnectX-5 Ex MCX516A-CDAT MCX516A-CDAT Specifications on page 64 MCX512A-ACAT MCX512A-ACAT Specifications on page 65 MCX512F-ACAT MCX512F-ACAT Specifications on page 66...
  • Page 63: Mcx516A-Bdat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 64: Mcx516A-Cdat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 65: Mcx512A-Acat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 66: Mcx512F-Acat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 67: Mcx515A-Gcat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 68: Mcx516A-Gcat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 69: Mcx515A-Ccat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 70: Mcx516A-Ccat Specifications

    Airflow Specifications on page 71 Safety: CB / cTUVus / CE EMC: CE / FCC / VCCI / ICES / RCM Regulatory RoHS: RoHS Compliant a. Typical power for ATIS traffic load. b. For both operational and non-operational states. Rev 1.7 Mellanox Technologies...
  • Page 71: Airflow Specifications

    Passive Active 1.5W Active 2.5W Active 3.5W Active 5W MCX516A-BDAT – MCX516A-CDAT 1000 1400 MCX512A-ACAT – – – MCX512F-ACAT – – MCX515A-GCAT – MCX516A-GCAT – MCX515A-CCAT MCX516A-CCAT 1300 a. Cells marked with (–) are not applicable Rev 1.7 Mellanox Technologies...
  • Page 72: Board Mechanical Drawing And Dimensions

    7.10 Board Mechanical Drawing and Dimensions All dimensions are in millimeters. All the mechanical tolerances are +/- 0.1mm. For the 3D Model of the card, please refer to Models. Figure 5: Mechanical Drawing of Dual-port x16 Adapter Cards 142.24mm 68.9mm Rev 1.7 Mellanox Technologies...
  • Page 73: Figure 6: Mechanical Drawing Of The Dual-Port X8 Adapter Card

    Specifications Figure 6: Mechanical Drawing of the Dual-port x8 Adapter Card 142.24mm 68.9mm Rev 1.7 Mellanox Technologies...
  • Page 74: Bracket Mechanical Drawing

    Specifications 7.11 Bracket Mechanical Drawing Figure 7: Single-port Tall Bracket 21.59mm 121.05mm Rev 1.7 Mellanox Technologies...
  • Page 75: Figure 8: Dual-Port Tall Bracket

    Specifications Figure 8: Dual-port Tall Bracket 21.59mm 121.05mm Rev 1.7 Mellanox Technologies...
  • Page 76: Appendix A Finding The Mac And Serial Number On The Adapter Card

    MAC for the Ethernet protocol . The revision indicated on the labels in the following figures do not necessarily represent the latest revision of the card. Figure 9: MCX512A-ACAT Board Label (Example) Figure 10: MCX512F-ACAT Board Label (Example) Rev 1.7 Mellanox Technologies...
  • Page 77: Figure 11: Mcx516A-Bdat Board Label (Example)

    Figure 11: MCX516A-BDAT Board Label (Example) Figure 12: MCX515A-GCAT Board Label (Example) Figure 13: MCX516A-GCAT Board Label (Example) Rev 1.7 Mellanox Technologies...
  • Page 78: Figure 14: Mcx515A-Ccat Board Label (Example)

    Figure 14: MCX515A-CCAT Board Label (Example) Figure 15: MCX516A-CCAT Board Label Example) Figure 16: MCX516A-CDAT Board Label (Example) Rev 1.7 Mellanox Technologies...
  • Page 79: Appendix B Safety Warnings

    6. Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regula- tions. 7. Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical codes. Rev 1.7 Mellanox Technologies...
  • Page 80 Caution – Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure. CLASS 1 LASER PRODUCT and reference to the most recent laser standards: IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+ A2:20. Rev 1.7 Mellanox Technologies...
  • Page 81: Avertissements De Sécurité D'installation (Warnings In French)

    L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur. 7. Codes électriques locaux et nationaux Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux. Rev 1.7 Mellanox Technologies...
  • Page 82 Mise en garde – l'utilisation de commandes ou de réglages ou l'exécution de procédures autres que ce qui est spécifié dans les présentes peut engendrer une exposition au rayonnement grave. PRODUIT LASER DE CLASSE 1 » et références aux normes laser les plus récentes CEI 60 825-1 Rev 1.7 Mellanox Technologies...
  • Page 83: Sicherheitshinweise (Warnings In German)

    6. Geräteentsorgung Die Entsorgung dieses Geräts sollte unter Beachtung aller nationalen Gesetze Bestim- mungen erfolgen. 7. Regionale und nationale elektrische Bestimmungen t Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen Bes- timmungen installiert werden. Rev 1.7 Mellanox Technologies...
  • Page 84 8. Strahlenkontak Achtung – Nutzung von Steuerungen oder Einstellungen oder Ausführung von Prozeduren, die hier nicht spezifiziert sind, kann zu gefährlichem Strahlenkon- takt führen. Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards : ICE 60 825-1 Rev 1.7 Mellanox Technologies...
  • Page 85: Advertencias De Seguridad Para La Instalación (Warnings In Spanish)

    La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales. 7. Códigos eléctricos locales y nacionales Este equipo se debe instalar conforme a los códigos eléctricos locales y nacionales. Rev 1.7 Mellanox Technologies...
  • Page 86: Rev 1.7 Mellanox Technologies

    Precaución: el uso de controles o ajustes o la realización de procedimientos distintos de los que aquí se especifican podrían causar exposición a niveles de radiación peligrosos. PRODUCTO LÁSER DE CLASE 1 y referencia a las normas de láser más recientes: IEC 60825-1 Rev 1.7 Mellanox Technologies...

Table of Contents