3.11. Display Power Saving Mode
The LED display turns off after three minutes if there is no action detected from the keypad.
3.12. Stopping the Pump
If the pump is stopped normally by pressing the Button "O", the "POWER" LED flashes and the LED display window
shows "OFF". If the pump is stopped by a detected fault, the "POWER" LED flashes and the LED display window will
show an error code number. Refer to the error code chart for the error code number shown and its description of the
fault detected.
3.13. To Change the Default Preset Speed Settings
Press the button "1", "2" or "3" for the fixed speed which is to be changed. The LED window displays the current
speed, then press and hold the "SET" button for at least three (3) seconds until the speed displayed in the LED window
begins to flash. The speed can then be changed using the "
50 rpm. The upper limit of the speed is 3400 rpm and the lower limit is 1000 rpm. To save the set speed, confirm with
the "OK" button. To cancel and return to the original speed press the "SET" button.
3.14. Lockout Keypad Programming
The keypad programming can be locked out for security to avoid unauthorized changes. The lock out function is
initialized by pressing the "O" and "SET" buttons simultaneously. Once the lock out security function is activated, a "."
(period) mark will be displayed at the right side of the LED display window. To unlock the security lockout function, just
repeat the same operation as above.
3.15. Recover Factory Default Speed Settings
The motor can be reset to the factory default speed settings by pressing the "SET" button for at least 15 seconds then
releasing it. The three LED's for the fixed speeds and the "POWER" LED turn on.
3.16. Fault Errors
In case of a fault error occurs, the "ERROR" light turns on and the LED display window displays an error code. The
message will not be cleared until the reason for the fault error is corrected. Refer to the error code chart for the error
code number shown and it's description of the fault detected.
To view the error records history, while in standby mode press the "O" button first and then press the "SET" button
within 1 second. Press the "
record. To delete all error records, press the "
nothing within 30 seconds will exit the error code view mode.
Page 10 of 20
▴
" button to go to the next error code. Press the "
▾
" button for at least 3 seconds. Pressing the "SET" button or doing
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
PowerFlo VS Variable Speed Pump
▾
▴
" or "
" buttons. The speed decreases or increases by
▾
" button to delete the current error
IS1580X15VSP Rev-A