Advertisement

Quick Links

ISVL1285 Rev B
VL Series Pump
®
Owner's Manual
NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and
completely.
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THIS INSTRUCTION MANUAL
Hayward Pool Products Canada
2880 Plymouth Drive, Oakville, ON L6H 5R4
Phone: 1.888.238.7665
Haywardpool.ca

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hayward VL Series

  • Page 1 ISVL1285 Rev B VL Series Pump ® Owner’s Manual NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely. READ AND FOLLOW ALL INSTRUCTIONS SAVE THIS INSTRUCTION MANUAL Hayward Pool Products Canada 2880 Plymouth Drive, Oakville, ON L6H 5R4 Phone: 1.888.238.7665...
  • Page 2: Table Of Contents

    Replacement Parts ............................. 11 8.1. Parts Diagram 8.2. Replacement Parts Listing Troubleshooting ............................12 9.1. General Problems Warranty ..............................14 Product Registration ........................... 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 2 of 15 VL Series Pump ISVL1285 Rev B...
  • Page 3: Important Safety Instructions

    – All electrical wiring MUST be in conformance with all applicable local codes, regulations, and the National Electric Code (NEC). USE OF NON-HAYWARD REPLACEMENT PARTS VOIDS WARRANTY. ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, OPERATION, AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT.
  • Page 4 Mechanical Entrapment - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught in an opening of a suction outlet cover resulting in mechanical entrapment. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 4 of 15...
  • Page 5 WARNING – Failure to install according to defined instructions may result in severe personal injury or death. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 5 of 15 VL Series Pump ISVL1285 Rev B...
  • Page 6: General Information

    2. General Information 2.1. Introduction This manual contains information for the proper installation and operation of the Hayward VL Series Pump. The instructions in this manual MUST be followed precisely. 2.2. Product Dimensions 3. Installation and Wiring WARNING – This product should be installed and serviced only by a qualified professional.
  • Page 7: Plumbing

    ATTENTION – Before removing strainer cover: STOP PUMP before proceeding. 2. CLOSE VALVES in suction and outlet pipes. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 7 of 15 VL Series Pump ISVL1285 Rev B...
  • Page 8: Maintenance

    Keep motor clean. Insure motor air vents are free from obstruction to avoid damage. Do NOT use water to hose off motor. • Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See “Shaft Seal Change Instructions” in this manual. 6. Storage / Winterization WARNING –...
  • Page 9: Shaft Seal Change Instructions

    • Disconnect all electrical power service to pump before beginning shaft seal replacement. • Only qualified personnel should attempt rotary seal replacement. Contact your local authorized Hayward Dealer or service center if you have any questions. • Refer to “Parts Diagram” section of this manual for pump component locations.
  • Page 10: Replacing The Motor Assembly

    (item #8) is in place, and lubricated. Replace if damaged). Tighten bolts alternately and evenly to 50-60 inch- pounds according to housing bolt torque pattern detail (Figure 7.6-1). Figure 7.6-1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 10 of 15 VL Series Pump...
  • Page 11: Replacement Parts

    8. Replacement Parts 8.1. Parts Diagram Figure 8.1-1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 11 of 15 VL Series Pump ISVL1285 Rev B...
  • Page 12: Replacement Parts Listing

    Motor Shuts OFF: Check for low voltage or power drop at the motor (frequently caused by undersized wiring). Contact a qualified professional to verify the electrical connections. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 12 of 15 VL Series Pump...
  • Page 13 4. Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage, which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine. All seal leaks should be replaced at once. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 13 of 15 VL Series Pump...
  • Page 14: Warranty

    10. Warranty USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 14 of 15 VL Series Pump ISVL1285 Rev B...
  • Page 15: Product Registration

    INITIAL PRESSURE GAUGE READING (CLEAN FILTER) _______________________ PUMP MODEL __________________ *Retain this Warranty Certificate in a safe and convenient location for your records Register Warranty online at Haywardpool.ca USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 15 of 15 VL Series Pump ISVL1285 Rev B...