PCE Health and Fitness PCE-ORP 3 Operation Manual

PCE Health and Fitness PCE-ORP 3 Operation Manual

Microcomputer based orp & temperature pocket meter

Advertisement

Quick Links

Operation Manual
PCE-ORP 3
Microcomputer Based
ORP & Temperature
Pocket Meter
PCE-ORP 3
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Unit 11
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCE-ORP 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for PCE Health and Fitness PCE-ORP 3

  • Page 1 From outside US: +1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0 Fax: (561) 320-9176 Fax: (0) 2380 98703 9 info@pce-americas.com info@pce-instruments.co.uk www.pce-instruments.com/english www.pce-instruments.com Operation Manual PCE-ORP 3 Microcomputer Based ORP & Temperature Pocket Meter PCE-ORP 3...
  • Page 2: Table Of Contents

    ..........2 B. Soak the Electrode ...2 C. Setup and Calibrate the Electrode and Meter PCE-ORP 3 OVERVIEW..........3 ..........3 A. Meter Description PCE-ORP 3 Graphical Display .......3 OPERATION MODES AND KEYPAD OPERATIONS..4 ...........4 A. Operation Modes ..........4 B. Keypad Operations USING PCE-ORP 3............5...
  • Page 3: Initial Inspection And Assembly

    2. Soak the ORP electrode in standard solution or distilled water for 10 minutes before first use or after storage. C. Setup and Calibrate the Electrode and Meter PCE-ORP 3 must be setup and calibrated before your first use. Please follow the instructions detailed in section USING VPCE-...
  • Page 4: Pce-Orp 3 Overview

    3. Keypad 4. Electrode collar 5. Electrode & ATC assembly (Electrode cap is not shown.) B. PCE-ORP 3 Graphical Display 1. DATE (MM-DD-YY) 2. ABSolute or RELative ORP mode indicator 3. HOLD mode indicator 4. TIME (HH:MM – 24H format) 5.
  • Page 5: Operation Modes And Keypad Operations

    OPERATION MODES AND KEYPAD OPERATIONS A. Operation Modes . PCE-ORP 3 meter has 7 operation modes: 1. Measure Mode.--Measure Mode is used to make all absolute or relative ORP and temperature measurements. 2. Calibration Mode.--Calibration Mode is used to perform offset voltage adjust.
  • Page 6: Using Pce-Orp 3

    Erase 0 second Exits Erase Mode USING PCE-ORP 3 A. Power ON/OFF & Shutdown Press “HOLD” key for 2 seconds or more. The unit will turn on and enter the “Measure Mode”. Repeat the process to turn off the unit.
  • Page 7: Relative Orp Calibration

    XX. The unit will automatically returns to “Measure Mode” and ready to perform other task. Note: The PCE-ORP 3 is equipped with a non-volatile memory that can store up to 50 different sets of readings...
  • Page 8: Recall Data

    (ABSolute & RELative mV, temperature, Time and date).Non- volatile memory will be retained even if power is lost. When all 50 memory locations are used up, the next set of data saved will overwrite the data stored in the first location and so on. G.
  • Page 9: Error Displays And Troubleshooting

    ERROR DISPLAYS AND TROUBLESHOOTING DISPLAY Possible cause(s) Display Mode [Action(s)] Display "OVER" Measure a. Temperature outside –10.0 to + Value 100.0°C range. “UNDER” [Bring solution to a lower/higher temperature.] b. Bad sensor. [Replace new electrode module .] "OVER" -10.0~ Measure ORP value outside -1100 to +1100 100.0°C mV value.

Table of Contents