Siemens SINAMICS IOP-2 Operating Instructions Manual page 29

Intelligent operator panel 2
Hide thumbs Also See for SINAMICS IOP-2:
Table of Contents

Advertisement

Expert
● Expert is fixed assigned to the Power Modules PM230, PM250 and PM260 as soon as for
G120D, G110M and ET200pro FC-2. This setting corresponds to the existing wizard and
will also be assigned to existing projects. It allows to flexibly parameterize the drive, but
requires a detailed understanding of the drive.
Motor data identification (motor ID)
When selecting motor data identification (motor ID) with subsequent ramp-up to the
setpoint speed (p1900 = 11 or 12; 12 = standard setting based on SINAMICS Firmware
V4.7 SP3 with "Standard Drive Control" and "Dynamic Drive Control"), the motor is, upon
the first Power ON command, directly accelerated to the setpoint speed, following a short
delay time caused by the motor ID (approx. 15 to 30 s). From SINAMICS Firmware V4.7
SP6 the default setting for p1900 = 2.
Note
Macro source selection
During the basic commissioning process, the user will be presented with a list of preset
macros that determine the configuration of the converter. Every Control Unit Operating
Instructions contain a list of the macros that are specific for that particular Control Unit and
show the wiring configurations for each macro. For further information, see the relevant
Operating Instructions.
For more detailed information of the application classes, see the document at the link below:
Application classes (https://support.industry.siemens.com/cs/ww/en/view/109480663)
Intelligent Operating Panel 2 (IOP-2)
Operating Instructions, 04/2017, FW V2.0, A5E39549448B AA
WARNING
Wizards menu
5.1 Example Wizard
29