This manual contains important safety instructions. Please follow all instructions during installation. Read this manual thoroughly before unpacking,
installing or operating.
Caution: Risk of Electric Shock
The UPS contains batteries. The output outlets may be electrically live even when the UPS is disconnected from the AC mains.
The UPS contains potentially hazardous voltages. Do not open the units as there are no user serviceable parts. All maintenance and servicing
should be performed by qualified service personnel.
Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test
before servicing and use insulated tools.
NOTE:The UPS is designed to be for use with computer loads only.
Caution:Do not connect a laser printer to the UPS.
A laser printer draws significantly more power than other types of equipment and may overload the UPS.
1
Inspection
Inspect the UPS upon receipt.
Notify the carrier and dealer if there
is damage. The package is
recyclable; save it for reuse or
dispose of it properly.
Inspect accessories:
Power cable 1PCS
USER MANUAL 1PCS
4
ConnectModem/ Phone / Network for Surge Protection (Optional)
- For modem/phone line protection,
connect equipment to the RJ11
port using RJ11 cable.
- For surge protection, connect
equipment to the RJ45 port using
Ethernet/RJ45 cable.
7
Cold Start Function
When the UPS is OFF and no utility input
power is present, use the "Cold Start" feature
to apply power to the loads from UPS's battery.
Press the "ON/OFF" switch untilthe UPS
beeps.
FRONT PANEL EXPLANATIONS
800LS/1000LS–LED FRONT
PANEL (STANDARD)
Note:Once the battery is disconnected, the loads are not
protected from power outages.
Use an insulated philip screwdriver to remove the four screws
1.
located
at the base of the UPS.
Remove the front panel and top cover.
2.
Disconnect the battery cable terminals before removing the
3.
battery from the UPS.
Step1: Loosen the black cable from the negative (-) terminal.
Step2: Loosen the red cable from thepositive (+) terminal.
USER'S MANUAL
2
Choose an installation location
- Avoid locations that are excessively humid, near water,
near heat sources or in direct sunlight
- Allow 1inch (2.5cm) clearance on each side of the UPS.
8
Software Download and Installation
Please follow steps below to download and install monitoring software:
1. Go to the website http://www.ablerex.com.sg/downloads.html
2. Depending on the computer OS, select Emily software (for Win 7&8 OS, select Emily2) and click download.
3. Follow the on-screen instructions to install the software.
4. When the computer restarts, the monitoring software automatically search and connects to the UPS.
LED
Symbol
Description/function
Color
Turn-on/Turn-off
N/A
Switch
Lit: Line mode
Dim: Abnormal input
Green
voltage and
frequency
Lit: Battery mode
Yellow
Flashing: Battery
Low
Lit: System
Red
malfunction
or abnormal
REPLACING THE BATTERY
800LS /1000LS
SETUP
3
5
ConnectInterface Device
The UPS is equipped with
two interface ports: a USB
port (Standard) and a 9-pin
RS232 port (Optional)
allowing advanced
communication network
between the UPS and a
computer (network).
800LS/1000LS REAR PANEL
4
1
2
Connect the battery cables to the terminals of thenew battery.
4.
Step1: Insert the black cable to the negative (-) terminal.
Step2: Insert the red cable to thepositive (+) terminal.
Note: Small sparks at the battery connectors are normal during connection.
Slide the battery into the UPS.
5.
Close the front panel and fasten the four screws located at the base of the UPS.
6.
Dispose off the old battery properly at an appropriate recycling facility.
7.
1
Connecting Equipment and Power to the UPS
Step1: Connect the UPS to the
AC mains.
Step2: Connect the equipment to
the UPS output outlets.
Step3: Switch on the AC Mains,
follow by the UPS then the
equipment last.
*Plug the UPS into the AC Mains
to charge for 8 hours before
using the UPS.
REAR PANEL EXPLANATIONS
Symbol
Description
1
2
3
3
4x Thailand Outlets
4
6
Turn ON/OFF the UPS
Turn on theUPS:Press the UPS
On/OFF Switchfor approx. 3
seconds, then the Buzzer sounds
twice, the UPS will start-up.
Turn off theUPS:Press the UPS
On/OFF Switchfor approx. 3
seconds, then the Buzzer
soundstwice, the UPS will
shutdown.
AC Input Outlet
Fuse
Output Connector:
USB (Standard)

Advertisement

loading

Summary of Contents for Ablerex 800LS

  • Page 1 Please follow steps below to download and install monitoring software: power is present, use the “Cold Start” feature 1. Go to the website http://www.ablerex.com.sg/downloads.html to apply power to the loads from UPS‘s battery. 2. Depending on the computer OS, select Emily software (for Win 7&8 OS, select Emily2) and click download.
  • Page 2 Replace the battery withthe same capacity. Step 6: Is the battery flat or defective? The Utility is normalbut Power cord is loose. Reconnect the power cordproperly. LED is flashing. Description Ablerex 800LS/1000LS SPECIFICATIONS Model 800LS 1000LS Capacity 800VA/400W 1000VA/600W Input...

This manual is also suitable for:

1000ls