Electrical Requirements

Electrical Requirements
This product is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, agency
approved, power supply kit with closed loop terminals
rated per the National Electrical Code, ANSI/NFPA 70-
latest edition (See Rating chart below). If local codes
prohibit grounding through the neutral, use a 4-wire,
agency approved, power supply kit with closed loop
terminals rated per the National Electrical Code,
ANSI/NFPA 70-latest edition (See Rating chart below).
RATING*
Specified Rating of Power Supply Cord
Kit and Circuit Protection
120/240 Volts
120/208 Volts
12.5 - 16.5 KW
9.2 - 12.5 KW
16.5 - 17.5 KW
12.5 - 13.5 KW
*The National Electric Code calculation for Electrical
Load is less than the Total Connected Electrical Load
listed on the model/serial rating plate.
A GFI shall be used if required by NFPA-70 (National
Electric Code), federal/state/local laws, or local
ordinances.
• The required use of a GFI is normally related to the
location of a receptacle with respect to any
significant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems
resulting from GFI outlets which are not installed
properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or
portable type NOT recommended)
• Used with permanent wiring only (temporary or
• On a dedicated circuit (no other receptacles,
• Connected to a standard breaker of appropriate size
• Rated for Class A (5 mA +/- 1 mA trip current) as per
• In good condition and free from any loose-fitting
• Protected from moisture (water, steam, high
Amps
40 or 50
50
Electrical
connection
in this area
6"
(15.2 cm)
4-3/8"
(11.1 cm)
8
portable wiring NOT recommended)
switches or loads in the circuit)
(GFI breaker of the same size NOT recommended)
UL 943 standard
gaskets (if applicable in outdoor situations)
humidity) as much as reasonably possible
WARNING
Electrical shock hazard.
To avoid the risk of electrical shock,
personal injury or death; verify
electrical power is turned off at the
breaker box until the range is installed and ready
to operate, installation by an authorized installer
only.
6"
(15.2 cm)