IRF2000 series – DNV GL variant
6.3.1 Power supply 24 VDC
The power supply is fed to the device via a lead-through terminal.
The voltage range is 18...36 VDC.
Pin
1
2
3
The figure shows the socket on the device.
The device must be connected to Functional Earth (FE).
Use a flexible cable with a wire cross section of 0.5 mm² / AWG20 and appropriate ferrules to maintain
the mechanical force at the connector, as low as possible.
Recommendation for use:
The distance between the casing and plug should be at least approx. 30mm
amount.
6.3.2 LAN (RJ45)
Pin
1
2
3
4
5
6
7
8
Fig.: The figure shows the socket on the device.
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen
Signal
24 VDC
GND
FE
Signal
D1+
D1-
D2+
D3+
D3-
D2-
D4+
D4-
27