ADS-tec IRF2000 series Instruction Manual

Dnv gl variant. it infrastructure
Hide thumbs Also See for IRF2000 series:
Table of Contents

Advertisement

Version 2.4
Updated 2018-09-12
Translation of the original
instruction manual
Instruction manual
IT Infrastructure
IRF2000 series – DNV GL variant

Advertisement

Table of Contents
loading

Summary of Contents for ADS-tec IRF2000 series

  • Page 1 Version 2.4 Updated 2018-09-12 Translation of the original instruction manual Instruction manual IT Infrastructure IRF2000 series – DNV GL variant...
  • Page 2: Table Of Contents

    Safety instructions concerning mobile telephony and GNSS (GPS) 3.10 Calculation example for the transmission power (EIRP) Introduction ........................... 17 Cut & Stop Alarming Eventlog Mobile phone modem Variants Scope of delivery Environmental conditions © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 3 Manual configuration of the network adapter Settings for use with Internet Explorer 8 Calling up the device web interface Technical details........................34 Service & support ........................35 ADS-TEC support Company address © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 4: Notes

    German instruction manual. 1.2 Limitation of liability ads-tec GmbH shall not be liable for personal injury, property damage or damage caused to the product as well as consequential damage that is/was the result of non-compliance with this instruction manual,...
  • Page 5: Manufacturer

    IRF2000 series – DNV GL variant 1.3 Manufacturer The manufacturer of the product is ads-tec GmbH. The company is referred to in the following as ADS- TEC. 1.4 Relevant device documentation The following documents are decisive to unit setup and operation: •...
  • Page 6: Safety Instructions

    Indicates a possible danger. If not avoided, light or minor injuries could result. ATTENTION Indicates a possibly damaging situation. If not avoided, the system or something in its surroundings could be damaged. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 7: Symbols

    All data, text and figures were prepared to the best of our knowledge. They do not represent any assurance for the properties themselves. Despite taking utmost care, no liability can be assumed for accuracy, completeness and actuality of the information. Subject to changes. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 8: Trademarks

    StoraXe® and Big-LinX® are registered trademarks of ADS-TEC. All other third-party trademarks used are hereby acknowledged. In the case of infringement of trademark rights, ADS-TEC reserves the right to exercise all rights. 2.7 Copyright This instruction manual is protected by copyright. For the authorised user, simple usage rights are granted within the scope of the intent of the contract.
  • Page 9: Compliance

    GL Rules shall be provided upon installation on board. ATTENTION Disturbance of the function of compasses by radio-frequency fields! • Observe the minimum permissible distance between the device and compasses of 17 cm. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 10: Operating And Safety Instructions

    Recommendation for use: Only the original ADS-TEC firmware / software is allowed for any of the settings and features described in this instruction manual. Loading of any firmware / software that has not been released by ADS-TEC invalidates the warranty.
  • Page 11: Safety Instructions

    Disregarding this warning can result in burn injuries or damage to property. Recommendation for use: Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges. (DIN EN 61340-5-1 / DIN EN 61340-5-2) © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 12: Operating Location

    3.4 Warranty / repairs During the device warranty period, any repairs must only be performed by the manufacturer or by service personnel that has been authorised by the manufacturer. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 13: Intended Use

    In the case of improper use, ADS-TEC shall not accept responsibility or liability for injury or damage that is directly or indirectly attributable to the handling of the device.
  • Page 14: Treatment And Disposal Of Lithium Batteries

    Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges. The provisions of DIN EN 61340-5-1 / DIN EN 61340-5-2 apply. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 15: Safety Instructions Concerning Mobile Telephony And Gnss (Gps)

    Strong electromagnetic radiation is considered hazardous to health. • In accordance with the rules of FCC/IC (Industry Canada), maintain at all times a separation distance of at least 20 cm between the antenna and the user’s body. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 16: Calculation Example For The Transmission Power (Eirp)

    = 22 dBm - 8 dB + 9 dBi = 23 dBm (≙ 200 mW) loss gain EIRP = Equivalent Isotropically Radiated Power = Transmission power of the device = Losses caused by attenuation in the coaxial cable loss = Antenna gain gain © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 17: Introduction

    The event log can be read out both locally and via a central syslog server. 4.4 Mobile phone modem Connection is possible via LTE/UMTS/GSM using the integrated modem. The SIM card slot is on the rear of the device. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 18: Variants

    4.7 Environmental conditions The device can be put into operation and used under the following conditions. Failure to observe any one of these conditions will invalidate the warranty. ADS-TEC cannot be held liable for any damages arising from improper use and handling.
  • Page 19: Assembly

    IRF2000 series – DNV GL variant 5 Assembly 5.1 External dimensions IRF22x0 – DNV GL version Fig. 1: IRF22xx – GL version © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 20: Mounting Options

    IRF2000 series – DNV GL variant 5.2 Mounting options 5.2.1 Table mounting Remove the protective foil on the rubber feet and attach them at the marked positions. Fig. 2 © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 21: Wall Mounting

    If the screws are too long, they could touch the printed circuit board inside the housing and cause a short circuit.  Only use screws with an adequate length. Fig. 3 © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 22: Top-Hat Rail Mounting

    Damage to the device due to vibrations The device could be damaged by horizontal vibrations.  The device must be fixed adequately in order to protect it from vibrations. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 23: System Features

    The status of the various interfaces is displayed via the integrated LEDs. Status diagnostics of the firewall can thereby be made at the installation site. The status indicators of the device are shown in the overview. LED status Representation Green Flashing green Orange Flashing orange © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 24: Front Leds

    Firmware is being updated, flashes rapidly (5 Hz) The device is supplied with voltage and is ready for operation. Status (3) This device is not supplied with voltage. Error during the boot-up process / recovery image. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 25: Operational Led Status Indicators

    Initialisation begins after the update procedure has been performed successfully. The PWR LED flashes slowly during this phase. • During a firmware update of the WWAN module, the 4G LED flashes yellow at a frequency of 5 Hz. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 26: Interface Overview Irf22X0 - Dnv Gl Version

    11. SCM card reader (read in/out the ADS-TEC memory cards) 12. 4G SIM card reader (LTE functionality) 13. Rail latch Recommendation for use: All input voltages can be connected redundantly © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 27: Power Supply 24 Vdc

    Recommendation for use: The distance between the casing and plug should be at least approx. 30mm amount. 6.3.2 LAN (RJ45) Signal Fig.: The figure shows the socket on the device. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 28: Wan (Rj45)

    The Cut & Alarm connection is fed to the device via a lead-through terminal. Signal 24 VDC IN (CUT) OUT (ALARM) Fig.: The figure shows the socket on the device. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 29: Usb Connections

    Complex IT infrastructures with a large number of devices can be managed, monitored and controlled easily and conveniently using Big-LinX. The Smartcard is available in the package with Big-LinX or as an individual accessory part. Further information on Big-LinX can be found at: http://www.ads-tec.de/industrial-it/cloud-big-linx/big-linx.html © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 30: Putting Into Operation

    When placing into operation for the first time, a connection is required between the device and a PC via an RJ45 network cable. Connect the device to a PC: Device LAN connection  PC LAN connection © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 31: Manual Configuration Of The Network Adapter

    Once the IP address has been entered, the subnet mask address must be entered. Click on the Subnet mask field and the correct address is entered automatically. Subnet mask: 255.255.255.0 Confirm your entries by clicking on OK. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 32: Settings For Use With Internet Explorer 8

    3. In the Add this website to the zone address line, enter the device IP address and confirm with Add. Default IP address: http://192.168.0.254 The IP address now appears in the list under Websites. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 33: Calling Up The Device Web Interface

    In this case, it is possible to select the "Bypass proxy server for local addresses" option to enter the address in question. The device web interface then appears Fig. 8 © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 34: Technical Details

    Ambient temperature in operation -20°C ... + 70°C for storage -20°C ... + 85°C Recommendation for use: Detailed information about the device can be found on our website http://www.ads-tec.de © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany...
  • Page 35: Service & Support

    ADS-TEC will not be able to answer such questions. ADS-TEC does not provide support services for any device that was not purchased directly from ADS- TEC. In this case, maintenance and support is provided by the partner company.