Mitsubishi Electric Melservo-J4 Instruction Manual page 99

General-purpose ac servo. servo amplifier
Hide thumbs Also See for Melservo-J4:
Table of Contents

Advertisement

Alarm No.: 8D
Name: CC-Link IE communication error
 MR-J3-T10 came off.
Alarm content
 An error occurred in CC-Link IE communication.
Detail
Detail name
Cause
No.
8D.1
CC-Link IE
(1)
communication
error 1
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
8D.2
CC-Link IE
Check it with the check method for [AL. 8D.1].
communication
error 2
8D.3
Master station
(1)
setting error 1
(2)
(3)
(4)
(5)
Check method
The MR-J3-T10 came
Check if [AL. 74 Option
off during the CC-Link
card error 1] occurred
IE communication.
with alarm history.
The Ethernet cable was
Check the Ethernet cable
disconnected.
connection.
The CC-Link IE
Check if the
communication was
communication was
disconnected by using
disconnected by using
a wrong procedure.
the correct procedure.
The wiring of the
Check if the wiring of
Ethernet cable was
Ethernet cable is correct.
incorrect.
An Ethernet cable was
Check if the Ethernet
disconnected.
cable is malfunctioning.
The transmission status
Check the noise, ambient
of the CC-Link IE
temperature, etc.
communication is
abnormal.
MR-J3-T10 is
Replace the MR-J3-T10,
malfunctioning.
and then check the
repeatability.
The servo amplifier is
Replace the servo
malfunctioning.
amplifier, and then check
the repeatability.
The master station is
Check if the master
malfunctioning.
station is malfunctioning.
The station No. is set to
Check the [Pr. Po02]
a value other than 1 to
setting.
120 with the master
station.
The network number is
Check the [Pr. Po03]
set to a value other than
setting.
1 to 239 with the master
station.
MR-J3-T10 is
Replace the MR-J3-T10,
malfunctioning.
and then check the
repeatability.
The servo amplifier is
Replace the servo
malfunctioning.
amplifier, and then check
the repeatability.
The master station is
Check if the master
malfunctioning.
station is malfunctioning.
Check result
It is occurring.
It did not occur.
It is disconnected.
It is connected.
The communication was
disconnected by using a
wrong procedure.
The communication was
disconnected by using
the correct procedure.
The wiring is incorrect.
The wiring is correct.
It has a failure.
It has no failure.
It has a failure.
It has no failure.
It is not repeatable.
It is repeatable.
It is not repeatable.
It is repeatable.
It has a failure.
The setting value is
incorrect.
The setting value is
correct.
The setting value is
incorrect.
The setting value is
correct.
It is not repeatable.
It is repeatable.
It is not repeatable.
It is repeatable.
It has a failure.
1 TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
Action
Target
Check it with the check
[RJ010]
method for [AL. 74].
Check (2).
Turn off the control circuit
[RJ010]
power supply of the
[GF]
servo amplifier, and then
connect the Ethernet
cable.
Check (3).
Follow the correct
procedure for
disconnecting the
communication.
Check (4).
Wire it correctly.
Check (5).
Replace the Ethernet
cable.
Check (6).
Take countermeasures
against its cause.
Check (7).
Replace the MR-J3-T10.
Check (8).
Replace the servo
[RJ010]
amplifier.
Check (9).
Replace the master
[RJ010]
station.
[GF]
Set it correctly.
[RJ010]
Check (2).
Set it correctly.
Check (3).
Replace the MR-J3-T10.
Check (4).
Replace the servo
amplifier.
Check (5).
Replace the master
station.
1.4 Remedies for alarms
1
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents