No.
Name/Description
38
MC drive circuit error
• Magnetic contactor drive
circuit is malfunctioning.
The main circuit power
supply is not supplied even
if the magnetic contactor
output is turned on.
The main circuit power
supply is supplied even if
the magnetic contactor
output is turned off.
39
Open phase
• The wirings of L1/L2/L3 are
incorrect.
3A
Inrush current suppression
circuit error
• The inrush current
suppression circuit error
was detected.
45
Main circuit device overheat
• The inside of the resistance
regeneration converter unit
overheated.
3 TROUBLESHOOTING FOR MR-CR55K(4) RESISTANCE REGENERATION CONVERTER UNIT
150
3.3 Remedies for alarms
Cause
Check method
(1)
The connection to the
Check the output of
magnetic contactor
magnetic contactor
connector (CNP1) is
control connector
incorrect.
(CNP1).
(Power supply voltage is
applied to this connector.
Take care to avoid an
electric shock at
connecting.)
(2)
The setting value of [Pr.
Check the [Pr. PA02]
PA02 Magnetic
setting and the wiring
contactor drive output
constitution.
selection] contradicts
the wiring constitution.
(3)
The voltage of the main
Check if the bus voltage
circuit power supply is
is lower than the
low.
prescribed value.
200 V class: 215 V DC
400 V class: 430 V DC
(4)
The magnetic contactor
Replace the magnetic
failed.
contactor, and then
check the repeatability.
(5)
Magnetic contactor
Replace the resistance
drive circuit is
regeneration converter
malfunctioning.
unit, and then check the
repeatability.
(6)
A part in the resistance
Replace the resistance
regeneration converter
regeneration converter
unit is failure.
unit, and then check the
repeatability.
(1)
Any of the wirings L1/
Check if the wirings of
L2/L3 is disconnected.
L1/L2/L3 are incorrect.
Or, disconnected.
(2)
A part in the resistance
Replace the resistance
regeneration converter
regeneration converter
unit is failure.
unit, and then check the
repeatability.
(1)
Turning on and off of
Check if the inrush relay
the inrush relay were
is turned on and off very
repeated very
frequently.
frequently.
(2)
Inrush current
Replace the resistance
suppressor circuit is
regeneration converter
malfunctioning.
unit, and then check the
repeatability.
(1)
Ambient temperature
Check the ambient
has exceeded 55 .
temperature.
(2)
Turning on and off were
Check if the overload
repeated under the
status occurred many
overload status.
times.
(3)
A cooling fan, heat sink,
Clean the cooling fan,
or openings is clogged
heat sink, or openings,
with foreign matter.
and then check the
repeatability.
(4)
The resistance
Replace the resistance
regeneration converter
regeneration converter
unit is malfunctioning.
unit, and then check the
repeatability.
Check result
Action
It is not correct.
Connect it correctly.
It is correct.
Check (2).
The setting or wiring is
Review the [Pr. PA02]
incorrect.
setting.
The setting and wiring
Check (3).
are correct.
The bus voltage is lower
Increase the voltage of
than the prescribed
the main circuit power
value.
supply.
The bus voltage is the
Check (4).
prescribed value or
higher.
It is not repeatable.
Replace the magnetic
contactor.
It is repeatable.
Check (5).
It is not repeatable.
Replace the resistance
regeneration converter
unit.
It is not repeatable.
Replace the resistance
regeneration converter
unit.
It has a failure.
Review the wiring.
It has no failure.
Check (2).
It is not repeatable.
Replace the resistance
regeneration converter
unit.
It is turned on and off.
Check operation pattern.
It is not turned on and off.
Check (2).
It is not repeatable.
Replace the resistance
regeneration converter
unit.
It is over 55 .
Lower the ambient
temperature.
It is less than 55 .
Check (2).
It occurred.
Check operation pattern.
It did not occur.
Check (3).
It is not repeatable.
Clean it periodically.
It is repeatable.
Check (4).
It is not repeatable.
Replace the resistance
regeneration converter
unit.