1.5

Remedies for warnings

CAUTION
If [AL. E3 Absolute position counter warning] occurs, remove the cause of the warning, and always make home position setting again. Otherwise, it may cause
an unexpected operation.
When any of the following alarms has occurred, do not cycle the power of the servo amplifier repeatedly to
restart. Doing so will cause a malfunction of the servo amplifier and servo motor. If the power of the servo
amplifier is switched off/on during the alarms, allow more than 30 minutes for cooling before resuming
operation.
• [AL. 91 Servo amplifier overheat warning]
• [AL. E0 Excessive regeneration warning]
• [AL. E1 Overload warning 1]
• [AL. E2 Servo motor overheat warning]
• [AL. EC Overload warning 2]
Warnings (except [AL. F0 Tough drive warning]) are not recorded in the alarm history.
If [AL. E6], [AL. E7], [AL. E9], [AL. EA], or [AL. EB] occurs, the amplifier will be the servo-off status. If any other warning
occurs, operation can be continued but an alarm may take place or proper operation may not be performed.
Remove the cause of warning according to this section. Use MR Configurator2 to refer to the cause of warning occurrence.