3-12. Installing the Rear Panel on the Wall

KH(S)2672R
Be sure to confirm that the wall is strong enough to suspend
the unit.
See either Item a) or b) below depending on the wall type.
a) If Wooden Wall
(1) Attach the rear panel to the wall with the 10 screws provid-
ed. (Fig. 3-34)
If you are not able to line up the holes in the rear panel
with the beam locations marked on the wall, use toggle
bolts to go through the holes on the panel or drill 3/16 in.
dia. holes in the panel over the stud locations and then
mount the rear panel.
(2) Double-check with a ruler or carpenter's level that the
panel is level. This is important to install the unit properly.
(Fig. 3-35)
(3) Make sure the panel is flush against the wall. Any space
between the wall and unit will cause noise and vibration.
b) If Block, Brick, Concrete or Similar Type Wall
Make 3/16" dia. holes in the wall. Insert rawl plugs for appropri-
ate mounting screws. (Fig. 3-36)
KH(S)3072R, KH(S)3672R
Confirm that the wall is strong enough to support the unit.
a) If Wooden Wall
(1) Attach the wall fixture to the wall with the 12 screws pro-
vided. (Fig. 3-37) If you are not able to line up the holes in
the wall fixture with the beam locations marked on the
wall, use rawl plugs or toggle bolts to go through the holes
on the panel or drill 3/16 in. dia. holes in the wall fixture
over the stud locations.
(2) Check with a tape measure or carpenter's level that the
wall fixture is level. This is important so that the unit is cor-
rectly installed.
(3) Make sure the wall fixture is flush against the wall. Any
space between the wall and unit will cause noise and
vibration.
b) If Block, Brick, Concrete or Similar Type Wall
Make 3/16 in. dia. holes in the wall. Insert rawl plugs for
appropriate mounting screws. (Fig. 3-36)
Page 37
37
Fig. 3-34
Fig. 3-35
1-3/16" or more
3/16"
dia. hole
Rawl plug
(Field supply)
Fig. 3-36
Wall fixture
Fig. 3-37
K