Trikdis G17F Installation Manual

Trikdis G17F Installation Manual

Gsm communicator
Hide thumbs Also See for G17F:

Advertisement

Quick Links

GSM communicator G17F
INSTALLATION MANUAL
UAB "TRIKDIS"
Draugystės str. 17,
LT-51229 Kaunas
LITHUANIA
E-mail: info@trikdis.lt
Webpage:
www.trikdis.lt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G17F and is the answer not in the manual?

Questions and answers

Summary of Contents for Trikdis G17F

  • Page 1 GSM communicator G17F INSTALLATION MANUAL UAB “TRIKDIS” Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt...
  • Page 2: Table Of Contents

    ................................4 PECIFICATIONS ............................5 OMMUNICATOR BOARD .............................5 URPOSE OF TERMINALS ..........................5 IGHT INDICATION OF OPERATION ..............................6 EFORE YOU BEGIN CONNECT G17F TO TRIKDISCONFIG ........................6 : ..............................6 SING CABLE : ................................6 EMOTELY ............................7 TATUS BAR DESCRIPTION SET OPERATION PARAMETERS ..........................7 ............................7 YSTEM PTIONS WINDOW ...............................8...
  • Page 3: Safety Requirements

    GSM communicator G17F Safety requirements The security or fire alarm system should be installed and maintained by qualified personnel. Prior to installation, please read carefully this manual in order to avoid mistakes that can lead to malfunction or even damage to the equipment.
  • Page 4: Description

    GSM communicator G17F Description Communicator G17F can upgrade any fire alarm panel for event signaling via cellular network. When input is violated, the communicator transmits an event message to Alarm Receiving Centre (ARC). Communicator can also inform customers about security system events in Protegus apps or with SMS messages.
  • Page 5: Communicator Board

    GSM communicator G17F Communicator board 1) GSM antenna SMA connector 2) Light indicators 3) Frontal case opening slot 4) USB Mini-B port for communicator programming 5) Nano SIM card slot 6) Terminal for external connections Purpose of terminals Terminal Description...
  • Page 6: Before You Begin

    6) Particular security control panel`s installation manual. Order them separately from your local distributor. Connect G17F to TrikdisConfig Communicator can be configured using TrikdisConfig software for MS Windows OS via USB cable or remotely. IMPORTANT: To use remote configuration function, Protegus service must be enabled (See chapter: Reporting window).
  • Page 7: Status Bar Description

    Status bar Name Description IMEI/Unique ID IMEI number of the communicator Status Action status Device Communicator type (shows G17F) Serial number Bootloader version Firmware version Hardware version State Connection status Admin Access level (shows up after access code is confirmed)
  • Page 8: Users Window

    Serial – mandatory serial six-digit number (set previous step).  Name – give name to the module.  Firmware version – version will be shown when G17F is in working mode and detects module. Zones window → Zones settings tab Zones settings ...
  • Page 9: Zones Window → Zones Reporting Tab

    GSM communicator G17F  CID Code – zone Contact ID event code (will be set automatically when the zone function is selected). Zones window → Zones reporting tab Zones→Zones reporting This window will be shown only if at least one User is described in the 3.2 Users...
  • Page 10: Reporting Window

    GSM communicator G17F Reporting window Primary and Backup channels  Select communication Protocol – TCP/IP, UPD/IP, SMS, Protegus. If the TCP/IP or UDP/IP protocol will be used – enter ARC Domain or IP, Port and Encryption key. Choose the Backup protocol, and enter required data.
  • Page 11: Ystem Events Window Eporting Tab

    GSM communicator G17F  ARC – selected event report will be sent to ARC.  CID code – contact ID number.  SMS event text – received SMS text after CID event is triggered.  SMS restore text – received SMS text after CID event is restored.
  • Page 12: Physical Installation Process

    GSM communicator G17F Physical installation process Insert SIM card into the holder  Use only Nano SIM card.  SIM card must be registered to the GSM network if GPRS communication will be used; enable mobile data service.  To configure the communicator remotely, insert a SIM card with the PIN code request function disabled.
  • Page 13: Input Connection

    Maximum four iO-MOD modules can be connected to one communicator in one system.  Maximum eight iO or/and iO-WL modules can be in one system.  Temperature sensors and iButton key reader is not compatible with G17F. Turn on the power supply. ©1997-2017 Trikdis www.trikdis.com...
  • Page 14: Remote Control

    GSM communicator G17F Remote control SMS commands list SMS Commands are used to control the communicator remotely. As access code use “SMS password”, “_” represents a space. SMS command structure: Command_SMSpassword_Data. Examples For the exemplary purposes, SMS password is 123456.
  • Page 15: Pgm Control With Dtmf

    Add communicator in Protegus Protegus service is a Web Service for remote intrusion or fire alarm self–monitoring and control of both Trikdis and 3rd party devices via Web, iOS, or Android apps. 1) Log in or sign in to www.protegus.eu.
  • Page 16  If you do not have the file, the newest firmware file can be downloaded by registered user from www.trikdis.com , under the download section of the G17F communicator. Press Update [F12]. Wait for the prompt of update to complete.

Table of Contents