8.3

CANDIS display instrument

The instrument indicates:
Battery charge display (on board charger
65
only)
Capacity display bars
66
Battery residual charge status
Warning - pre-warning symbol,
67
Battery charge recommended
Stop symbol; lift cutout,
68
Battery charge required
T symbol appears during operation when
69
the discharge indicator is set to
maintenance-free battery
6 digit LCD display;
70
hourmeter, input display;
error display
In addition, service messages for the electronic components and parameter changes
are displayed.
Discharge status display
Setting limits for the additional "Warning" (67) and "Stop" (68) displays will depend on
the battery type.
The available capacity is shown via 8 LED bars.
The current battery capacity is shown by the illuminated LED bars. 8 bars correspond
to full battery capacity, 1 bar corresponds to the minimum available capacity.
If only one LED bar is lit, the battery capacity is almost depleted and the "Warning"
indicator (67) is lit. The battery must be charged immediately.
If no more LED bars are illuminated, the "Stop" indicator (68) lights up. Lifting is now
inhibited. The battery must be charged.
8.3.1 Discharge monitor function
When the discharge monitor function is enabled, lifting is cut out when reaching the
discharge limit is reached (the Stop LED goes on). Travel and lowering are still
possible.
65
67
69
66
68
70