RGH40 installation drawing

Reference mark actuator
(A-9531-0250)
Scale graduations
7
3
P limit magnet
(A-9531-0251)
Mount dimple down
(Dimensions same as Q limit)
2 mounting holes
M3 x 7.5 deep
Ø4.5 ±0.2
14.4
5.1
*
Extent of mounting faces.
The recommended thread engagement is 5 mm. The recommended tightening torque is between 0.5 and 0.7 Nm.
RGH40 RGS40-G
installation guide
R>50 Dynamic bend radius
R>10 Static bend radius
2 mounting holes M3 x 9.5 deep
6 min
14
4
4
14.6
14.6
P limit switch
sensor position
44
38
7.7
Arrow indicates optical and
reference mark centreline
Arrow indicates forward direction of
readhead relative to scale
Reference mark sensor position
Optical centreline
(Yaw tol. ±1°)
0.8
3
10
Q limit magnet
(A-9531-0251)
Mount dimple up for Q
Q limit switch
sensor position
3
(Pitch tol. ±1°)
0.8
2.9
4.9
Rideheight
0.8 ±0.15
(Roll tol. ±1°)
0.13
20.7
15.3
3.6
Set-up
LED
10.5
7.5
8.6
2.8
17
2.9
Optional bolted limit magnet
4.05
17.5
8.5
25.5
Dimensions and tolerances in mm
5.7
0.5 ±0.5
9
18
27
13
*
Mounting ledge or
top surface of bracket
for limit switch actuator
Optional bolted limit magnet
P
,
(A-9550-0047)
Q
(A-9550-0048)
3